Specialized Administration > Tailoring Business Objects > Type and Attribute Management > Type and Attribute Management Command-Line Tools > Exporting and Importing Type Information > Importing Types and Global Enumerations > Enabling Logging for Imports
  
Enabling Logging for Imports
Logging can be useful if you are experiencing issues importing type information. To enable logging for importing type information, complete the following steps:
1. Access the Log Levels page:
a. From Site > Utilities, under System Administration, select Server Status.
b. On the Server Status page, select Monitoring Tools.
c. On the System Health Monitoring Tools page, select Log Levels.
2. On the Log Levels page, under Server Processes, select the Method Servers and Servlet Engines processes.
3. In the Logger field, specify the class where you want to adjust the logger level. For load files, set the class to com.ptc.core.lwc.server.TypeDefinitionLoader.
4. From the Level drop-down list, select ALL.
5. Click Set.
6. Repeat steps 4 through 6 to set the logger level for the com.ptc.core.lwc.server.LoaderHelper class.