Additional Windchill Capabilities > Windchill Quality Management Solutions > Unique Device Identification > Working with Unique Device Identification > Importing and Updating a UDI Submission from a Spreadsheet
  
Importing and Updating a UDI Submission from a Spreadsheet
Importing Submissions from a Spreadsheet
Follow these steps to import a new UDI submission from a spreadsheet into Windchill.
You can download a sample spreadsheet from ptc.com and use it to create a UDI submission. For more information on creating submissions, see Creating a New UDI Submission in PTC Windchill.
1. From your UDI library context, click Folders or Details.
2. From the Actions menu, select Import from Spreadsheet.
3. In the Import from Spreadsheet window, in the Local File Path field, click Browse.
4. Navigate to your spreadsheet and then click Open. The file name appears in the File Name field.
5. From the Import Action list, select one of the following:
Add Only—Select this option to create a new UDI submission from a spreadsheet.
Add and Update—Select this option if you are not sure if the UDI submission exists in Windchill. If the UDI submission already exists, then it is updated with the new information from the spreadsheet. If the UDI submission does not exist, then it is created.
6. Click Next.
If messages appear in the Errors and Warnings table in the Validation step, correct the errors by editing and saving the spreadsheet. Click the revalidate spreadsheet icon to update the table.
If there are no errors or warnings, click Import.
Imported UDI submissions appear under Folder Contents in the Creation state. In the My Tasks table, the system creates a UDISubmission Creation task for each line of the spreadsheet.
7. To update the UDI information, right-click the UDISubmission Creation task and select Edit UDI Submission. Complete the information in the Edit UDI Submission window. For more information, see Completing the UDI Submission Form.
8. Click Finish to move the UDI submission to the approval step.
Updating Submissions from a Spreadsheet
Follow these steps to update existing UDI submissions that were created from a spreadsheet in Windchill.
* 
Existing submissions cannot be updated in the In Progress, Delayed, or Submission states. Submissions in the Closed state are iterated and updated, and then the system sets the state to Creation.
If the correct information is present in the spreadsheet, the system updates the part details, linked parts, related objects, and UDI data.
1. From your UDI library context, click Folders or Details.
2. From the Actions menu, select Import from Spreadsheet.
3. In the Import from Spreadsheet window, in the Local File Path field, click Browse.
4. Navigate to your spreadsheet and then click Open. The file name appears in the File Name field.
5. From the Import Action list, select one of the following:
Add and Update—Select this option if you are not sure if the UDI submission exists in Windchill. If the UDI submission already exists, then it is updated with the new information from the spreadsheet. If the UDI submission does not exist, then it is created.
Update Only—Select this option to update an existing UDI submission with information from the spreadsheet.
6. Click Next.
If messages appear in the Errors and Warnings table in the Validation step, correct the errors by editing and saving the spreadsheet. Click the revalidate spreadsheet icon to update the table.
If there are no errors or warnings, click Import.
Imported UDI submissions appear under Folder Contents in the Creation state.
7. To update the UDI information, right-click the UDISubmission Creation task and select Edit UDI Submission. Complete the information in the Edit UDI Submission window. For more information, see Completing the UDI Submission Form.
8. Click Finish to move the UDI submission to the approval step.
Completing the Spreadsheet
Complete the following tabs in the spreadsheet with the information you want to import into Windchill.
UDISubmission Data
Alternate Identifiers
Device Contact Information
FDA Product Code
GMDN Term Code
Premarket Authorization Number
FDA Listing Number
Sterilization Method
Device Size Characteristics
Storage and Handling Requirements
Packaging Configuration
The fields in each tab correspond to entries in the UDI submission form. For additional instructions to complete specific fields, see Completing the UDI Submission Form.
The following fields appear in each tab of the spreadsheet:
UDISubmission Name—The name of the UDI submission. This is a mandatory field in each tab.
Context of UDISubmission—If you do not specify this information, the system searches for the submission name in the context where the import action is performed.
UDISubmission Type—This allows the system to have a UDI submission with the same name but a different type. If you do not specify the type of UDI submission, the default is FDAUDISubmission.
* 
If you are completing the Sterilization Method tab, Sterilization Code is a mandatory field.
If you are completing the FDA Product Code tab, Product Code is a mandatory field.