Additional Windchill Capabilities > Manufacturing Process Management > Transforming an eBOM into an mBOM > Maintaining an mBOM > Propagating Upstream Changes
  
Propagating Upstream Changes
There may be some updates made to the upstream structure recently; for example, new parts added or existing parts removed. These updates may not be reflected in the downstream structure. You can use the Propagate Upstream Changes pane in Associative Part Structure browsers to update the downstream structure with the latest upstream changes. The application compares the current iteration of the upstream structure with the previous up-to-date iteration that was linked to the current downstream structure. You can review the detected changes and propagate the required changes to the downstream structure.
By default, equivalence association is used as the criterion to compare the iterations. You can change the criterion to compare based on baseline number or time duration. For more information, see Customizing the Comparison Mechanism.
To propagate upstream changes:
1. Click on the middle pane tool bar and select the appropriate parts in the upstream structure.
The Propagate Upstream Changes pane opens to the right of the browser.
* 
The mechanism for detecting upstream changes requires that you select a part in the upstream structure. The search then detects changes made for the nodes linked up to the first level. The selection made in the downstream structure does not impact the search results.
2. To search for the upstream changes based on a change notice created for an upstream part, enter the change notice or change task number in the Change Number box. The changes made on the resulting objects listed in the change notice or change task are detected.
* 
When using a change number, selecting a part in the upstream structure is not mandatory.
You can customize the search criterion for Change Number to detect the changes made through a promotion request. For more information, see Customizing Change Number Criteria.
3. Select the search criteria to specify the upstream changes that you want to view:
Criteria: To specify the comparison mechanism for detecting the upstream changes, select the appropriate mechanism from the Criteria list.
Baseline: Enter the baseline number in the adjacent box. The current iteration of the upstream structure is compared with the parts included in the specified baseline.
Out Of Date: The current iteration of the upstream structure is compared with the previous up-to-date iteration that was linked to the current downstream structure.
Duration: Enter the duration in the adjacent box. The current iteration of the upstream structure is compared with the iteration available before the specified duration.
You can filter the search result by specifying the type of upstream changes to be listed, using the All Changes list.
Out of Position: Detects parts with updated location coordinates.
Usage Expressions: Detects parts with updated expressions assigned to usage links. The supported expressions are basic and advanced. Usage Expressions also detects concatenated expressions. However, independent assigned expressions are not detected.
Occurrence Expressions: Detects parts with updated expressions assigned to occurrences. The supported expressions are basic and advanced. Occurrence Expressions also detects concatenated expressions. However, independent assigned expressions are not detected.
Removed Parts: Detects parts that were removed.
Added Parts: Detects parts that were added.
* 
For the Added Parts criteria, you can control the way the detected parts are transferred to the downstream structure during the propagation. For more information, see Configuring and Customizing Automatic BOM Transformation.
Quantity: Detects parts with updated quantity values.
Usage Attributes: Detects parts with updated values for usage attributes that are defined in the standard MPMLink carryover framework. Out of the box, the Usage Attributes criterion detects changes for the Find Number attribute. You can customize the criterion to detect the attributes of your choice. For more information, see Customizing Part Attributes and Usage Attributes Criteria.
The criterion supports local and global attributes. It does not support dependent attributes, such as alias, cascaded, and calculated.
Part Attributes: Detects parts with updated values for the associated attributes including classification attributes. The attributes must be defined in the standard MPMLink carryover framework. Out of the box, the Part Attributes criterion detects changes for the Source and Assembly Mode attributes. You can customize the criterion to detect the attributes of your choice. For more information, see Customizing Part Attributes and Usage Attributes Criteria.
The criterion supports local and global attributes. It does not support dependent attributes, such as alias, cascaded, and calculated.
Replaced Parts: Detects parts that were replaced with new parts, existing parts, alternate or substitute parts, and peer equivalent parts.
Effectivity: Detects parts with updated effectivity values for the types: lot, block, serial, MSN, and date. Changes in effectivity values are detected only when a part is revised.
* 
You can add or remove the change types given in the All Changes list. For more information, see Configuring Discrepancy Types and Supporting Interfaces.
4. Click Search.
The box in the Upstream Changes panel displays the search result of the search task. The table lists the changes detected for the parts in the upstream structure. Each row in the table displays the updated part details and the current and previous values for a change type. For more information on the current and previous values, see Current and Previous Values for Discrepancy Types.
The table also includes the following status for each change:
Resolved: The changes in the upstream structure are already resolved in the downstream structure.
Auto: The changes in the upstream structure can be propagated to the downstream structure using the action.
Manual: The changes in the upstream structure cannot be propagated using the default logic.
5. Select the changes that you want to propagate to the downstream structure, and click .
* 
The selection made in the downstream structure does not impact the propagation results.
* 
Instead of using the Propagate changes to downstream action, you can use a workflow event to sync the downstream structure with the latest upstream structure. For more information, see Propagating Changes Using a Workflow Event.
6. Click OK to confirm.
The box in the Resulting Downstream Changes panel displays the result of the propagation task. The table lists the changes that were propagated to the downstream structure. Each row in the table displays the updated part details and the updated and previous values for a particular change type. For more information on the current and previous values, see Current and Previous Values for Discrepancy Types.
The changes that are successfully propagated to the downstream structure are grayed out in the Upstream Changes table. The changes that were not selected or could not be propagated, continue to appear in the Upstream Changes table.
The following status for each change appears in the Upstream Changes and Resulting Downstream Changes tables:
Resolved: The upstream changes are propagated to the downstream structure.
Failed: The upstream changes cannot be propagated.
* 
After propagating a change, it is recommended to update the equivalent link for the corresponding parent node in the downstream structure. This ensures that subsequent searches for upstream changes provide relevant information.
The following actions are available in the Upstream Changes and Resulting Downstream Changes table tool bar.
Icon
Action
Description
Clear all
Clears the selected entries.
Select all
Selects all the entries listed in the table.
Invert selection
Inverses the current selection. Clears current selection and selects the entries that are not selected.
Select in structure
Highlights the parts that are associated with the selected changes in the upstream or downstream structure.
* 
Click or Clear All Highlighted Rows action on the menu to remove highlights from the selected parts.
Propagate changes to downstream
Propagates the changes selected in the Upstream Changes table to the Resulting Downstream Changes table.
Search
Refines the result based on the keywords specified in the Search box.
Propagating Effectivity in MAPSB
Effectivity settings are propagated from an upstream part to a downstream part when the following conditions are met:
Effectivity is assigned to an upstream part.
No effectivity is assigned to the corresponding downstream part.
The com.ptc.windchill.mpml.copyOver.mapsb.newBranch.create.wt.part.WTPart property is configured in the mpmlink.properties.xconf file, which is located at Windchill\codebase\com\ptc\windchill\mpml\xconfs.
If the above conditions are satisfied, the effectivity values of upstream parts are propagated to corresponding downstream parts when structure transformation actions are executed.