Enterprise Administration > Windchill Data Loading > Loading Documents: Pro/INTRALINK Example
  
Loading Documents: Pro/INTRALINK Example
This section provides a detailed example of the data loading process for documents in a Pro/INTRALINK system.
Loading Documents in a Pro/INTRALINK System
In Pro/INTRALINK, you use PDM capabilities to manage CAD documents and documents. Pro/INTRALINK supports loading of documents, but does not support loading of CAD documents through the LoadFromFile framework.
The process for loading documents to Pro/INTRALINK is the same as loading parts or CAD documents into another Windchill solution. For more information, see The Data Loading Process.
The load utility is preceded by windchill. An example command for loading documents is:
windchill wt.load.LoadFromFile -d ProIDoc.xml -CONT_PATH "/wt.inf.container.OrgContainer=TST/wt.pdmlink.PDMLinkProduct=p art 4\"
* 
Run the utility from the same directory where the data file resides.
Loading a Library
The command for loading a library to Pro/INTRALINK resembles the following:
windchill wt.load.LoadFromFile -d OneDocSet.xml -CONT_PATH \
"/wt.inf.container.OrgContainer=carrie/wt.inf.library.WTLibrary=