|
If both the Basic and Advanced tabs appear, you can move from Basic to Advanced, but if you change the configuration criteria or rule criteria, data may be lost. Data can also be lost if you change one or more rules and then move from Advanced to Basic. A window appears, allowing you to confirm that you want to move to the Basic mode or to cancel the action.
|
Control
|
Description
|
(Filter properties) |
Opens the Filter Properties window, displaying the current dependency processing, including the Type and Details.
|
(Edit filter) |
Opens the Edit Filter window, allowing you to edit the filter applied to the selected structure.
For more information, see the Windchill Help Center topic, “Editing a Structure Filter.”
|
|
Depending on the action you are performing, you may only see some of the action options in the following table. Depending on the action you are performing, other menus, such as File and Edit may appear in the menu bar to allow you to make other operation-specific selections. Additional actions may also appear in the collector table toolbar, depending on the operation that you are performing.
|
Action
|
Description
|
||
Configuration
|
Select configuration options for the collection (for example, Current Settings field, above the table of objects.
> > ). The configuration option currently selected is reported in the |
||
Add Dependency
|
Specify which types of dependents are to be included. You may be able to choose All, Required or None, depending on the initially selected object type.
The Add Dependency action is available from the Configuration menu on the table.
|
||
Click the advanced collection icon to open the Advanced Add window that allows you to collect certain additional object types (for example, source and derived CAD documents).
|
|||
Click the add parts icon to collect parts associated to the selected object.
|
|||
Click the add drawings icon to collect all drawings associated to the selected part or CAD document.
|
|||
Click the add family objects icon to collect all family table objects related to the selected generic or instance.
|
|||
Click the add generics icon to collect the generic associated to selected instances.
|
|||
Click the add CAD/dynamic documents icon to collect all CAD or dynamic documents associated to the selected part.
|
|||
Click the add ECAD objects icon to collect all ECAD objects associated to the selected object.
|
|||
Click the Collect related Enterprise Data objects icon to collect the common and view-specific enterprise data for the selected part.
|
|||
Click the Collect related Functional Data objects icon to collect any plant-specific functional data for the selected view-specific enterprise data object or part.
|
|||
Click the add documents icon to collect all documents related to the selected object.
|
|||
Click the add affected data icon to collect all affected data related to a selected change object. This applies for change objects that can have affected data, such as problem reports, analysis activities, change requests, and change activities.
|
|||
Click the add change objects icon to open a window that allows you to select which type of change object you want to collect. For more information, see the help available from that window.
|
|||
Click the add notes icon to collect all notes related to the selected object.
|
|||
Click the add specifications members icon to collect all specifications members related to the selected object.
|
|||
Click the add upstream linked objects icon to collect all upstream linked objects related to the selected object.
|
|||
Click the add downstream linked objects icon to collect all downstream linked objects related to the selected object.
|
|||
Click the remove icon to remove selected objects from the table.
|
|||
Click the include icon to include selected objects in the collection.
|
|||
Click the exclude icon to exclude selected objects from the collection.
|
|||
Click the reset icon to reset the collection to the initially selected objects. If you reset your collection, all additionally collected objects are removed from the entire table.
When you select this action, a warning message appears explaining that all data collected will be lost.
|
|||
Ignore objects in other contexts
|
This check box may appear below the collection table for some collection processes. When selected, only the objects located in the context of the seed objects are collected.
|
|
The part, drawing, and CAD document icons are present in all collection tables. The other actions appear as appropriate for the operation you are performing.
|
|
The Collection Rule column can be helpful by identifying the reason (rule) that caused an object to appear in the table. If a single rule applies to an object, that rule is displayed. If multiple rules apply (for example when an object is initially selected for an action and is also a dependent of another initially-selected object), then Multiple Rules is displayed. When you hover your cursor over text displayed in the Multiple Rules column, a tool-tip pops up, listing the applicable rules for the object in that row.
|
If the object set for which you are attempting to perform the transaction has issues that prevent a successful transaction, the Event Management utility opens, reporting on the status of the transaction. Use the Event Management page and the Conflict Management page to resolve overridable conflicts and retry the operation. |