Integration with Other Applications > Integrated Software Management > Software Configuration Management Integrations > Working with Windchill Integrations for Embedded Software Objects > Accessing and Managing Migrated Data > Working with Migrated Documents
  
Working with Migrated Documents
Windchill Integrations for Embedded Software provides an integrated environment to manage migrated documents from Windchill 9.x and 10.1x to Windchill 10.2.
A typical use scenario is migrating Windchill 9.x documents with IBM Rational ClearCase attachment content to Windchill 10.2 that includes Windchill Integrations for Embedded Software with IBM Rational ClearCase.
Documents in Windchill 9.x can have IBM Rational ClearCase attachments.
Documents in Windchill 10.2 cannot have IBM Rational ClearCase attachments. Instead, a related software document contains the IBM Rational ClearCase attachment content.
Documents in Windchill 10.2 can have non-software attachment content.
Documents in Windchill 10.2 can have related objects. A related object can be a software document.
Migrated Documents with only Primary Source Content — Not applicable for IBM Rational ClearCase Content
In the conversion process, a document with only primary source content converts to an updated document with primary source content, as in the Windchill 9.x system.
For example, if migrating a document with a local file content, like an MS Word document, the migrated document converts to an updated document with MS Word primary source content, as in the originating Windchill 9.x system.
Migrated Documents with IBM Rational ClearCase Primary Source Content
In the conversion process, a document with IBM Rational ClearCase primary source content becomes two Windchill objects: (1) an updated document and (2) a related software document. Documents in Windchill 10.2 cannot have IBM Rational ClearCase primary source content.
The document information includes all of the originating document information from the Windchill 9.x system, except for the IBM Rational ClearCase primary source information.
The IBM Rational ClearCase primary source content is converted to a related software document of which the name and other information is generated from the updated document. For example, IBM Rational ClearCase primary source content from the migrated document converts to a related software document with IBM Rational ClearCase primary source content.
Migrated Documents with Attachment Content — Not applicable for IBM Rational ClearCase Attachment Content
In the conversion process, a document with attachment content converts to an updated document in Windchill 10.2. The updated document includes all of the originating document information from the Windchill 9.x system.
* 
Documents in Windchill 10.2 cannot have IBM Rational ClearCase attachments.
Migrated Documents with IBM Rational ClearCase Attachment Content
In the conversion process, a document with IBM Rational ClearCase attachment content becomes two Windchill objects: (1) an updated document and (2) a related software document. Documents in Windchill 10.2 cannot have IBM Rational ClearCase attachments.
The document information includes all of the originating document information from the Windchill 9.x system, except for the IBM Rational ClearCase attachment information.
The IBM Rational ClearCase attachment information is converted to a related software document of which the name and other information is generated from the updated document. For example, IBM Rational ClearCase attachment content from the migrated document converts to a related software document. If there was no migrated primary source content, one of the IBM Rational ClearCase attachments converts to the IBM Rational ClearCase primary source content in the related software document. Remaining IBM Rational ClearCase attachments convert to IBM Rational ClearCase attachments in the related software document.
Where Do I Find My Migrated Documents?
A migrated document can be accessed and managed from Products > Folders, Projects > Folders, or Libraries > Folders in Windchill.
Once you have located the document in the Folders table, click the document information page to access the Details, Structure, Related Objects, Changes, History, Where Used, and Traceability tabs. Click New Tab and Customize to add or remove available tab tables.
For migrated documents with non- IBM Rational ClearCase primary source or attachment content, click the document information page Content tab to access the content in the Primary Content and Attachments tables.
For migrated documents with IBM Rational ClearCase attachment content, click the document information page Related Objects tab to access the related software document in the References Documents table.
Refer to the following table for information on how to access and manage software documents and related software documents.
Windchill Object
Description
Migrated Document
Refer to Managing Documents for information on how to create, edit and delete documents, or to learn about documents.
Related Software Document
Refer to Working with Related Software Documents to learn about related software documents.
Refer to Working with Software Documents for information on how to create, edit and delete software documents, or to learn about software documents.