If you modify any global variables you must redeploy the application for any changes to take effect. The description for any global variable can be viewed as a tool-tip from the TIBCO Administrator GUI, by placing the mouse pointer over the respective global variable.
|
Global Variable Group
|
Description
|
ESIClassName
|
This group contains the global variables that represent the class names of various objects like parts, BOMs, CNs, and process plans. If class names are changed in Windchill then these values also need to be changed accordingly.
These variables are used to compare and identify a type of object. Based on the identified type, a message is written to the Process Archive log.
|
ESIConstants
|
This group contains global variables for constant values; For example actions like Create, Change, Unchange, Delete and for boolean values like true, false.
|
ESIFlags
|
This group contains global variables that define actions based on the boolean value they are set to.
|
ESIJMS
|
This group contains global variables for JMS connection and related activities.
|
ESILog
|
This group contains global variables used to configure and identify the information that needs to written to the Process Archive log.
|
ESIMessaging
|
This group contains global variables used to configure and identify the information that needs to be sent to Windchill.
|
ESIMail
|
This group contains global variables used for configuring e-mail parameters.
|
ESIPaddingTruncate
|
This group contains global variables used to configure lengths for padding and truncation. Padding is automatic when certain object numbers are numeric. Truncation is based on the values set for the global variables in the ESIFlags group. For example; truncateNameDescription_Enable (SAP only).
|
ESIOthers
|
This group contains various other independent global variables used in the business logic.
|
|
These global variables should not be modified until they have been first modified in Windchill.
|
Global variable name
|
Description
|
Default Values
|
BOMClass
|
Class name for the BOM object
|
com.ptc.windchill.esi.BOMHeader
|
DocumentClass
|
Class name for the Document object
|
com.ptc.windchill.esi.Document
|
DocumentLinkClass
|
Class name for the DocumentLink object
|
com.ptc.windchill.esi.DocumentLink
|
ECNClass
|
Class name for the ECN object
|
com.ptc.windchill.esi.ChangeHeader
|
OperationClass
|
Class name for the Operation object
SAP only.
|
com.ptc.windchill.esi.mpml.Operation
|
PartClass
|
Class name for the Part object
|
com.ptc.windchill.esi.Part
|
ProcessMaterialClass
|
Class name for the ProcessMaterial object
SAP only.
|
com.ptc.windchill.esi.mpml.ProcessMaterial
|
ReleaseResultClass
|
Class name for the Result method specified by the global variable ESIOthers/WCPostResultMethod.
|
com.ptc.windchill.esi.ReleaseResult
|
ProcessPlanClass
|
Class name for the Process Plan object.
|
com.ptc.windchill.esi.mpml.ProcessPlan
|
ResourceClass
|
Class name for the Resource object
SAP only.
|
com.ptc.windchill.esi.mpml.Resource
|
SequenceClass
|
Class name for the Sequence object.
SAP only.
|
com.ptc.windchill.esi.mpml.Sequence
|
ToolingClass
|
Class name for the Tooling object
SAP only.
|
com.ptc.windchill.esi.mpml.Tooling
|
|
These global variables should not be modified. These values are used extensively in the EAI business logic.
|
Global variable name
|
Description
|
Default Values
|
CHANGE
|
Action Flag for modified objects
|
Change
|
CREATE
|
Action Flag for new objects
|
Create
|
DELETE
|
Action Flag for deleted objects
|
Delete
|
UNCHANGE
|
Action flag for unchanged objects
|
Unchange
|
TRUE
|
Represents the boolean value True
|
true
|
FALSE
|
Represents the boolean value False
|
false
|
Global variable name
|
Description
|
Possible Values and Windchill ESI Defaults
|
JNDIContextURL
|
The JMS JNDI context URL.
tibemsnaming://<EMS Server
Name>:<EMS Server Port>
|
Default:tibemsnaming://localhost:7222
|
Username
|
The user used to logon to JMS through the EAI
|
Default : ESISYS
|
Password
|
The password for the user used to logon to JMS through the EAI.
|
Default : ESISYS
|
RetryCount
|
The number of times to attempt sending a result message to JMS before suspending the job.
|
Any integer.
Default: 3
|
RetryPeriod
|
The time in seconds to delay between consecutive attempts to send a result message to JMS
|
Any integer.
Default: 300
|
MaxSessions
|
The maximum number of JMS sessions to be created for incoming messages.
|
1
|
|
Windchill JMS configurations may also need to be modified to support the new queue.
|
Global variable name
|
Description
|
Possible Values and Windchill ESI Defaults
|
DataResponseQueue
|
The DataResponse queue name for the JMS interface with Windchill. This value must match the DataResponse queue name specified on the TIBCO EMS server and byWindchill ESI Services.
|
In SAP
• Default:com.ptc.windchill.esi. DataResponse.<<system ID>>.<<client>>
Where <<system ID>> is the system name for the SAP distribution target. and <<client>> is the client for the SAP system. For example, 800.
<<system>> and <<client>> must match the values specified for the attributes System ID and Client respectively of the distribution target in Windchill.
In Oracle Applications:
• Default: com.ptc.windchill.esi.DataResponse.<DSN>
Where
<DSN> is the ODBC datasource name for Oracle Apps underlying database connection.
This is the same value that is provided for ESIOMAdapter/Datasource global variable.
|
ResultQueue
|
The Result queue name for the JMS interface with Windchill PDMLink. This value must match the Result queue name specified on the TIBCO EMS server and byWindchill ESI services.
|
Default:com.ptc.windchill.esi.Result
|
Global variable name
|
Description
|
Possible Values and Windchill ESI Defaults
|
||
ERPPrimary
|
The flag to enable logging of ERP Primary messages.
|
Integer value 1 = on; 0 = off; Default: 1
|
||
ERPSecondary
|
The flag to enable logging of ERP Secondary messages.
|
Integer value: 1 = on; 0 = off; Default: 1
|
||
Functional_Debug
|
The flag to enable logging of Type functional (1) and Severity debug (9) messages
|
Integer value: 1 = on; 0 = off; Default: 0
|
||
Functional_Error
|
The flag to enable logging of Type functional (1) and Severity error (1) messages
|
Integer value: 1 = on; 0 = off; Default: 1
|
||
Functional_Informational
|
The flag to enable logging of Type functional (1) and Severity informational (4) messages.
|
Integer value: 1 = on; 0 = off; Default: 0
|
||
Functional_Success
|
The flag to enable logging of Type functional (1) and Severity success (3) messages.
|
Integer value: 1 = on; 0 = off; Default: 1
|
||
Functional_Warning
|
The flag to enable logging of Type functional (1) and Severity warning (2) messages.
|
Integer value: 1 = on; 0 = off; Default: 1
|
||
RootCause
|
The flag to enable logging of root cause messages.
|
Integer value: 1 = on; 0 = off; Default: 1
|
||
Technical_Debug
|
The flag to enable logging of Type technical (2) and Severity debug (9) messages.
|
Integer value: 1 = on; 0 = off; Default: 0
|
||
Technical_Error
|
The flag to enable logging of Type technical (2) and Severity error (1) messages
|
Integer value: 1 = on; 0 = off; Default: 1
|
||
Technical_Informational
|
The flag to enable logging of Type technical (2) and Severity informational (4) messages.
|
Integer value: 1 = on; 0 = off; Default: 0
|
||
Technical_Success
|
The flag to enable logging of Type technical (2) and Severity success (3) messages.
|
Integer value: 1 = on; 0 = off; Default: 1
|
||
Technical_Warning
|
The flag to enable logging of Type technical (2) and Severity warning (2) messages.
|
Integer value: 1 = on; 0 = off; Default: 1
|
||
Delimiter
|
The delimiter used when logging messages
|
Any character. Default: , (comma)
|
||
Locale
|
Locale used to lookup logging message text.
|
Default: en_US
Following are valid locale values:Language / Country / Locale Encoding Value English / United States / en_US
English / United Kingdom / en_GB
French / France/ fr
German / Germany / de
Italian / Italy/ it
Spanish / Spain/ es
Japanese / Japan/ ja
Chinese Simplified / China (PRC) / zh_CN
Chinese Traditional / Taiwan / zh_TW
Korean / Korea / ko
Brazilian Portuguese / Brazil / pt_BR
On Windows:
To set your system encoding to, for example, Japanese, on an English operating system:
1. Click Start>Settings>Control Panel.
2. Click Regional Options.
3. Change the locale encoding to Japanese.
4. Make sure that Japanese is checked in the language settings for the system. If you do not have the languages installed on your operating systems, refer to the Microsoft support site for help.
To view the log files on an English operating system:
1. Open the file in any text editor such as Notepad, that can display international characters.
2. Select the font as MS PMincho.
To view the log files in Internet Explorer:
If you do not have a text editor that can display international characters, view it in Internet Explorer by doing the following:
1. Rename the file with a .txt extension
2. Set the encoding value to Shift-JIS by selecting View > Encoding > More >Japanese (Shift_JIS)
To view the log files in the TIBCO Administrator GUI:
1. Select the tracing tab of the components of both the process engine and the adapters.
2. View the log file. If the characters appear incorrect, perform the next step.
3. Stop and restart all of your TIBCO services.
4. View the log file again.
|
Global variable name
|
Description
|
Possible Values and Windchill ESI Defaults
|
||||
BCCAddress
|
An optional field set to copy someone (using the BCC e-mail feature) on the alert e-mail message sent to the administrator when there is an error in the Result or the ResultResponse messages.
|
Any single valid e-mail address, or a series of valid e-mail addresses separated by commas.
|
||||
CCAddress
|
An optional field set to copy someone (using the CC e-mail feature) on the alert e-mail message sent to the administrator when there is an error in the Result or the ResultResponse messages.
|
Any single valid e-mail address, or a series of valid e-mail addresses separated by commas.
|
||||
FromAddress
|
A required field that should be set to the designated e-mail address of the sender of e-mail alert messages when there is an error in the Result or ResultResponse messages. This e-mail address appears in the From field.
|
Any single valid e-mail address.
|
||||
SMTPHostServer
|
The value of the SMTP host server. Contact your IT department to get this value.
|
Typically, a string that describes the server name, such as: mail.mycompany.com
|
||||
ToAddress
|
A field that should be set to the e-mail address of theWindchill ESI administrator. The administrator gets an e-mail with the alerts if there is an error in the Result or ResultResponse message. The administrator could then examine the errors, make the appropriate fixes, and resume the process.
|
Any single valid e-mail address, or a series of valid e-mail addresses separated by commas.
Note: You can also use the optional CCAddress and BCCAddress variables.
|
|
The default value of each global variable is also the length of the relevant attribute, as defined in SAP. Also, padding will occur provided the value of the attribute is all numeric. Truncation will occur if the global variable ESIFlags/TruncateNameDescription_Enable is set to true
|
Global variable name
|
Description
|
Possible Values and Windchill ESI Defaults
|
PaddingNumber_DocumentLength
|
Used for padding the number attribute on a document, so as to make its length equal to that defined in SAP.
|
25
|
PaddingNumber_ECNLength
|
Used for padding the number attribute on a CN, so as to make its length equal to that defined in SAP.
|
12
|
PaddingNumber_PartLength
|
Used for padding the number attribute on a part, so as to make its length equal to that defined in SAP for a Material.
|
18
|
PaddingNumber_ResourceLength
|
Used for padding the number attribute on a resource, so as to make its length equal to that defined in SAP for a Material.
|
18
|
PaddingNumber_SequenceLength
|
Used for padding the number attribute on a sequence, so as to make its length equal to that defined in SAP for a Material.
|
6
|
PaddingNumber_SerialEffectivityLength
|
Used for padding the serial number in serial effectivity, so as to make its length equal to that defined in SAP.
|
18
|
TruncateDescript_ECNLength
|
Used for truncating the description attribute on a CN, so as to make its length equal to that defined in SAP.
|
40
|
TruncateName_ECNLength
|
Used for truncating the name attribute on a CN, so as to make its length equal to that defined in SAP.
|
40
|
TruncateName_DocumentLength
|
Used for truncating the name attribute on a document, so as to make its length equal to that defined in SAP.
|
40
|
Global variable name
|
Description
|
Possible Values and Windchill ESI Defaults
|
||
WCResponseDirectory
|
When the global variable ESIFlags/ WriteResponseToFile flag is set to ‘true’ theWindchill ESI Response data will be written to a file and that file will be stored inside this folder.
The file name format is determined by the value of the global variable ESIOthers/ ResponseFileName, with the transaction number appended to its end.
|
<tibco_home>/esi/bin/
|
||
SAPDateFormat
|
The date format that the distribution target expects (the date format of the user that is logged onto the distribution target). The format must use valid TIBCO notation.
|
Default: yyyy-MM-dd
This value must match the date format that is configured in the SAP system for theWindchill ESI user, specified for the global variable ESISAPAdapter/Username.
|
||
SAPMPMDateFormat
|
The SAP ECC date format that the Routing API and the ECN APIs expect for a Routing object.
|
Default: yyyyMMdd
This value must match the date format that is configured in the SAP system for theWindchill ESI user, specified in the ESISAPAdapter/Username global variable.
|
||
APIRetryPeriod
|
The time (in milliseconds) the TIBCO BusinessWorks engine should wait for a response from an adapter before sending an error message.
|
Any integer value
Default: 300000
|
||
BWInvokeBindExceptionClass
|
The name of the exception class for adapter bind errors.
|
Default:BindException
|
||
BWInvokeTimeOutClass
|
The name of the exception class for adapter time-outs.
|
Default:ActivityTimedOutException
|
||
BWKillProcess
|
Used by the ErrorHandling_Service to intentionally end the process when a fatal error occurs.
|
Default: KillProcess
|
||
WCPostResultMethod
|
The method name for post result messages.
|
Default: PostResult
This value must match the RPC name for PostResult messages inWindchill ESI Services for the class identified by the global variable ReleaseResultClass under the ESIClassNames global variable group.
|
||
WSHost
|
The host name for the ERP part information web service.
|
This can be a machine name or a WebServer domain name.
Default: localhost
|
||
WSPort
|
The port number for the ERP part information web service.
|
Any port number ranging from 1024 to the maximum value supported on the machine.
Default :6666
|
||
WCDateFormat
|
The date format expected from Windchill PDMLink.
The format must use valid TIBCO notation.
|
Default: yyyy-MM-dd HH:mm:ss
This value must match the date format used in messages sent from Windchill PDMLink.
|
||
ResponseFileName
|
Filename for the Response data sent by Windchill for a transaction.
|
ESIResponseFromWC_.xml
|
||
WSRequestResponseFileName
|
Filename for the Request data sent by Windchill to the ERP Part Information web service.
|
ESISOAP_.xml
|
||
ReplaceZeroQuantityWith
|
If quantity is set to “0” in Windchill then the value defined for this global variable will be used for quantity
|
Possible value: Integer > 0
Default value: 9999999999
|
||
PartBatchSize
|
The number of part that should be processed via a single call to SAP BAPI.
|
Possible value: any integer > 0.
Default value: 100
|
Global variable name
|
Description
|
Possible Values and Windchill ESI Defaults
|
||
ApplicationServer
|
The application server connection string of the distribution target.
|
The valid values for the application server string when making one of the following connections:
• Through a firewall or an SAP router:
/H/<SAP Router>/S/<SAP Router Service>/W/<Password>/H/<Target Application Server>
where:
<SAP Router> is the IP address or name of the SAP router.
<SAP Router Service> is defaulted to 3299.
<Password> indicates the password for the connection between the predecessor and successor on the route and is also optional. The default is "" that is, no password.
<Target Application Server> is the IP address or name of the SAP application server.
• On the same network:
Enter the IP address or the application server name of the SAP server:
<Target Application Server>
|
||
SystemID
|
The Windchill PDMLink identifier for the System ID attribute of the distribution target. This value appears in the value of Destination element sent in the response message from Windchill as in <SystemID>.< Client>
|
For SAP systems, this is typically a three-character string. This variable is used in the TIBCO Rendezvous subject name when publishing messages to the TIBCO Adapter for ECC instances. The ESI distribution target System ID value sent in the ESIResponse message by Windchill PDMLink must match the System value set in the corresponding TIBCO Adapter for ECC instances to ensure successful publishing of messages to the adapter instances and ultimately to SAP.
|
||
Client
|
The client number of the distribution target.
|
Value is the three-digit client number of the distribution target. This variable is used in the TIBCO Rendezvous subject name when publishing messages to the TIBCO Adapter for ECC instances. The ESI distribution target client value sent in the ESIResponse message by Windchill PDMLink must match the Client value set in the corresponding TIBCO Adapter for ECC instances to ensure successful publishing of messages to the adapter instances and ultimately to SAP.
|
||
CommitExpiry
|
Session Timeout in milli seconds for SAP “Commit Required” BAPIs.
|
360000
|
||
SystemNumber
|
The system number of the distribution target.
|
This is a two-digit integer value.
|
||
Username
|
The username used to log onto the distribution target.
|
This value could be any string. Default user name is: ESISYS.
|
||
Password
|
The password used to log onto the distribution target.
|
Value could be any string.
|
||
Locale
|
The locale of the distribution target. Determines the subject name the adapter is listening on.
|
The following are the ISO standard locale values. Default is en_US
Following are valid locale values :Language / Country / Locale Encoding Value
English / United States / en_US
English / United Kingdom / en_GB
French / France/ fr
German / Germany / de
Italian / Italy/ it
Spanish / Spain/ es
Japanese / Japan/ ja
Chinese Simplified / China (PRC) / zh_CN
Chinese Traditional / Taiwan / zh_TW
Korean / Korea / ko
Brazilian Portuguese / Brazil / pt_BR
This variable is used in the TIBCO Rendezvous subject name when publishing messages to the TIBCO Adapter for ECC instances. The com_infoengine_locale JMS header property value sent in the ESIResponse message by Windchill PDMLink must match the Locale value set in the corresponding TIBCO Adapter for ECC instances to ensure successful publishing of messages to the adapter instances and ultimately to SAP.
|
||
MaxConnections
|
The number of SAP connections in the client connection. This option is used to configure the maximum number of threads in the adapter instance.
|
By default, it is set to 5. A maximum of 99 connections is allowed.
|
||
ReconnectionAttemptsNumber
|
Number of Reconnect Attempts before suspending impacted service(s). In other words, it is the number of times the connection management process tries to connect to the application before the listener for a subscription or a one-way Request-Response Invocation service is suspended.
|
The default value for this field is 1.
|
||
MaxReconnectionAttempts
|
Maximum number of Reconnect Attempts - the maximum number of times the adapter will retry to establish a connection to the SAP ECC system.
|
By default, it is set to 1. This has to be greater than or equal to the value specified for the global variable ReconnectionAttemptsNumber. For the adapter to keep retrying forever, set the value to -1.
|
||
ReconnectionAttemptsInterval
|
Interval between Reconnect Attempts (milliseconds) The time interval between two successive retries, in milliseconds.
|
The default value is 30000 ms.
|
||
LogFilesizeLimit
|
Maximum size of the log file, in bytes.
|
Default is 3000000. Maximum is 2147483647 bytes.
|
||
LogFileCount
|
The number of Adapter Log files to be generated viz., the number of roll over files.
|
Default is 3.
|
||
JMSProviderURL
|
JMS Provider URL to connect to the EMS server by Adapter JMS transport.
|
Default is set to: tcp://<<EMSservername>>:7222
|