This section lists the most “frequently used” preferences, and not every preference that can be set using the wgmclient.ini file. Refer to the wgmclient.ini file, located in your Windchill Workgroup Manager home directory, for a complete list of preferences.
|
Name
|
Description
|
Values
|
checkin.content.options
|
Specifies how the model is saved on the authoring application menu, Auto Check In and provides default interface setting for Custom Check In.
|
• Models Only (default)
• Viewables Only
• Models and Viewables
|
save_to_ws.content.options
|
Provides the default interface setting for the content option in the Tools menu of the Save To Workspace dialog.
|
• Models Only (default)
• Viewables Only
• Models and Viewables
|
save.upload
|
Specifies if the model is uploaded after a native Save action in the authoring application. For example,
> . |
• No (default)
• Yes
|
UndoCheckout.overwrite.local.content
|
Specifies if the model content is overwritten in cache by default when using Undo Checkout.
|
• No (default)
• Yes
|
overwrite.contents.on.update
|
Specifies if the model content is overwritten in cache by default when using Update from a Windchill Workgroup Manager.
|
• No (default)
• Yes
|
wgm.autoattach
|
Allows configuring the content that is uploaded as additional content of a model.
|
• CAD/Dynamic Document Type
• Attachment File Type
• Content Category
|
open.modifies.checkedout.objects
|
Determines how checked out models will appear in session after update.
|
• Yes (default)
• No
|
upload.related.drawings
|
Native upload or auto check in of CAD Documents will also upload or check in associated drawings.
|
• Yes (default)
• No
|
unmanaged.read.only.area.folders
|
Windchill Workgroup Manager will ignore files retrieved from specified file system paths assuming there is no need to manage these in Windchill. Windchill Workgroup Manager will not store these file in the WLD, will not perform checks against the Windchill database, and will not establish Windchill dependencies.
|
This preference takes a semi-colon separated list of folder paths that constitute the ROAs. Search path will include sub-folders.
|
force.update.metadata.on.open
|
Controls propagation of Windchill Workgroup Manager attributes as properties upon opening of models from workspace and allows delay of this propagation to get better performance during open.
|
• Yes (default)
• No
|
enable.replace.in.cad.session.on.refresh
|
Controls whether to enable the feature of Replace in CAD Session on refresh.
|
• No (default)
• Yes
|
cache.size
|
Specifies a limit for the client's internal cache.
|
• 0 (default)
• Set value in MB. For example, 800.
|
upload.autoattach.searchpath
|
Specifies paths on disk, separated by a semicolon (;), searched for attachments that need to be automatically added to a CAD/Dynamic Document upon upload.
|
User may use environment variables in search path specifying the environment variable as ${environment variable name}.
|
message.slider.timeout
|
Controls the duration that a pop-up message window stays on screen.
|
• 10 (default)
• 0 (disables slider window)
Enter an numeric value in seconds.
|
ascii.only.chars.in.workspace.name
|
Restricts ASCII characters in the workspace name. This preference turns onWindchill Workgroup Manager mapping of Unicode workspace name to an ASCII name in the Local Workspace.
|
• No (default)
• Yes
|
open.appVersionSelection.alwaysShowDialog
|
Determines whether dialog to choose an application version is always shown on openInSession.
|
• No (default)
• Yes
|
wwgm.remember.last.used.server
|
Controls whether to reconnect to last used server upon subsequent Windchill Workgroup Manager client launch.
|
• Yes (default)
• No
|
windows.browser.type
|
Sets the Windchill Workgroup Manager embedded browser type.
|
• For the Chromium browser type, enter: chromium_browser
• For the Internet Explorer browser type, enter: ie_browser
|
update.drawing.alwaysShowDialog
|
Determines whether to prompt the user with a dialog box to update the drawing upon save to workspace or checkin.
|
• Yes (default)
• No
|
wf.network.threads
|
Controls the number of network threads to be used upload and download content.
|
• 3 (default)
• Integer Value equal to or greater than 0
|
wwgm.open.dialog.remember.last.location
|
Controls whether to retain the last selected Folder in an Open Dialog upon open operations, such as Open from Windchill, Insert from Windchill, and Replace.
|
• Yes (default)
• No
|
java.script.errors
|
Controls the display and execution of the java script error dialogs. If the dialog is presented, the user can choose whether to stop or continue running the script.
|
• Show (default)
• Hide and run
• Hide and stop
|
enable.preselection.file.selection.dialog
|
Controls whether an object is selected by default in the file selection window for open actions for all Windchill Workgroup Manager clients. This includes actions such as Import to Workspace, Open from Windchill, Insert from Windchill, and Replace.
|
• Yes (default)—The first valid file is selected by default.
• No—No file is preselected.
|
add.to.workspace.replace.iteration.option
|
Controls whether the Add to Workspace action replaces local workspace iterations with different iterations selected in the commonspace.
|
• Conflict (default)—The action fails with an overridable conflict.
• Replace—The local workspace iterations are automatically replaced with selected ones from the server.
|
hide_default_workspaces.in_server_management
|
Control whether to display or hide virtual workspaces in the Server Management utility.
For more information, see Displaying or Hiding Virtual Workspaces in the Server Management Utility.
|
• No (default)
• Yes
|
workspace.autolock.for.no.modify.permission
|
When set to Yes, CAD Documents for which the user does not have Modify access will be automatically locked during Add to Workspace. Objects for which the user does have Modify access will not be locked.
For more information, see Locking and Unlocking Objects in the Workspace.
|
• No (default)
• Yes
|