Family Table Errors
This topic lists the family table error codes and their descriptions.
Group 1
These are critical errors. If unresolved, they can lead to runtime related errors. You must run WinDU FTValidator and WCTK FTHealer utilities to resolve these errors.
Severity
Error Code
Description
Impact
Error
20010
Standalone document participating in a containedin link.
None
Error
20020
Standalone document participating in a variant link.
None
Error
20190
CAD name of the document master not equal to the name of family table.
None
Error
20200
Standalone document participating in a containedin link.
None
Error
20220
Family table has containedin link with iterations from the same master.
Retrieve, check in, check out will fail
Error
20230
Standalone document participating in a variant link.
None
Error
20440
Family table is not associated with any containedin link.
None
Group 2
These are medium severity errors. You cannot open the related documents in Creo, if these errors remain unresolved.Run the WinDU FTValidator and WCTK FTHealer utilities to resolve these errors.
Severity
Error Code
Description
Impact
Error
20050
Top generic document participating as a variant.
None
Error
20060
Document not associated with any family table.
Retrieve, check in, check out will fail
Error
20080
Document participating in family table does not have any instance or column.
Retrieve, check in, check out will fail
Error
20210
containedin link between the same two objects.
None
Error
20150
Instance not participating in any variant link as a variant.
None
Error
20350
Instance iteration of the containedin link is part of two different family tables.
Retrieve, check in, check out will fail
Error
20360
containedin link doesn't exist between the found Family Tree and the found generic, for the instance document.
Retrieve, check in, check out will fail
Error
20370
Intermediate generic has no variant, and no columns defined at its level.
None
Error
20380
Navigation from variant to top-level generic is not possible with the instance document.
Retrieve, check in, check out will fail
Error
20390
Family table does not have one top-generic.
Retrieve, check in, check out will fail
Error
20420
Family table has no instance or column.
Retrieve, check in, check out will fail
Group 3
These are non-critical errors. If left unresolved, the family table may miss the parameter values or parameter column. We recommend running the WinDU FTValidator and WCTK FTHealer utilities to resolve these errors.
Severity
Error Code
Description
Impact
Error
20100
Checked out document associated with a checked in family table.
Check in, check out will fail
Error
20120
Document and associated family table not checked out to the same workspace.
Retrieve, check in, check out will fail
Error
20130
Family table has associated members from different namespace.
Retrieve, check in, check out will fail
Error
20140
Family table has associated members from different projects.
Retrieve, check in, check out will fail
Error
20340
Duplicate family table cell between the same two objects.
None
Error
20400
Associated members of the family table are in a checked out state.
Retrieve, check in, check out will fail
Error
20410
Associated members of the family table are not checked out to the same workspace as the family table.
Retrieve, check in, check out will fail
Warning
20450
Family table domain does not match the domain of the member ( top level if all members are in a project, otherwise member in project)
None
Warning
20520
Family table members(top generic, generic-instance, instance) have a reference to primary content.
None
Error
20530
Family table does not have primary content.
Retrieve, check in, check out will fail
Error
20540
Checkedout EPMSepFamilyTable has no checkedout members.
Check in, check out will fail
Warning
20470
CellDep does not have an associated MemberLink for the EPMFamilyTableMember column.
None
Warning
20480
CellDep does not have an associated ReferenceLink for the EPMFamilyTableReference column.
None
Warning
20490
Cell does not have associated parameter value for the EPMFamilyTableParameter column.
Adding objects to workspace fails with the server error: Cannot retrieve family table neutral data
Error
20500
Cell does not have associated Feature Value for the EPM Family Table feature column.
Adding objects to workspace fails with the server error: Cannot retrieve family table neutral data
Error
20510
Cell does not have an associated attribute value for the EPM Family Table attribute column.
Adding objects to workspace fails with the server error: Cannot retrieve family table neutral data
Group 4
These errors are warnings only and no action is required to resolve them.
Severity
Error Code
Description
Impact
Warning
20030
Standalone document having EPM an parameter value associated.
None
Warning
20040
Standalone document having an EPM feature value associated.
None
Error
20110
Iterations from the document master associated with family tables from different masters.
None
Error
20180
Instance participating in more than one containedin link.
None
Error
20240
Variant link between the same two objects.
None
Warning
20250
No feature definition in the family table master with the same name as feature value.
None
Warning
20270
No parameter definition in family table master with the same name as parameter value.
None
Warning
20290
No cell found with the defined flag set to 1 for the given column.
None
Warning
20310
Not all the intermediate instances have cells for the given column.
None
Warning
20320
Cell with defined Flag set to 1 are not associated with generic.
None
Warning
20330
Cell with defined Flag set to 0 are not associated with instance.
None
Error
20430
Family table does not have columns with unique names.
Retrieve, check in, check out will fail
Error
20460
ContainedInLink and FT column associated with a cell are not pointing to the same FT.
Adding objects to workspace fails with Server Error: Cannot retrieve family table neutral data