Integration with Other Applications > CAD Document Administration > CAD Document Limitations > Warning Messages Triggered by WinDU FTValidator During Family Table Import
Warning Messages Triggered by WinDU FTValidator During Family Table Import
On both the source and target systems, the family table FT1 A.1 includes the assembly FT1.ASM A.1 and its components Instance001 A.1 and Instance002 A.1. However, only FT1 A.1 and FT1.ASM A.1 are marked as ready for replication on the target system, while the instances are not.
Source System
Target System
FT1 A.1
FT1 A.1
FT1.ASM A.1
FT1.ASM A.1
Instance001 A.1
Instance001 A.1
Instance002 A.1
Instance002 A.1
During import, FT1 A.1 and FT1.ASM A.1 are successfully overwritten on the target system. However, because Instance001 A.1 and Instance002 A.1 were not marked as ready for replication, they are not overwritten. This results in an incomplete family table on the target system.
After a successful import, running the WinDU FTValidator reveals warning errors due to missing components and links:
Error Code
Severity
Description
20470
Warning
CellDep does not have associated MemberLink for the EPMFamilyTableMember column.
20480
Warning
CellDep does not have associated ReferenceLink for the EPMFamilyTableReference column.
Sample warning error displayed by WinDU FTValidator during family table validation, is as follows:
Group #3
Severity: Non-Critical Errors
Impact: Family Table might be missing parameter values or parameter column
Suggested Actions: run WinDU FTValidator, run WCTK to heal
--------------------------------------------------
ERROR_CODE NUMBER OF ERRORS DETECTED
--------------------------------------------------
20470 3
--------------------------------------------------