This property is deprecated from the Windchill 13.1.1.0 release and will be terminated in a future Windchill release.
|
|
|
For attributes of the Real Number with Units type, the property definition supports only the following OOTB quantities of measure (QoM):
• Count
• Length
• Mass
• MPM_ProcessPlan_QoM_CostUnit
• MPM_QoM_CostUnit
• MPMLink_Length
For more information about quantities of measure, see Managing Quantities of Measure in the “Working with the Type and Attribute Management Utility” section.
|
|
|
These properties are deprecated from the Windchill 13.1.1.0 release and will be terminated in a future Windchill release.
|
|
Name
|
Description
|
Default Value
|
|---|---|---|
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.ConfigurablePartUseDefinedValue
|
When the property is defined and set, Multi-Level BOM Roll-up uses the specified attribute value defined for configurable parts in the summation calculation. The attributes specified in a comma-separated list must be included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include an attribute, the attribute value defined for configurable parts is not included in the roll-up summation calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.EndItemDoNotUseDefinedValue
|
When the property is defined and set, Multi-Level BOM Roll-up uses the specified attribute value defined for end items in the summation calculation. The attributes specified in a comma-separated list must be included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include an attribute, the attribute value defined for end items is not included in the roll-up summation calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
Name
|
Description
|
Default Value
|
|---|---|---|
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowNumericSummationWithPartialValues
|
When the property is defined and set, the Multi-Level BOM Roll-up allows roll-up summation calculation for the specified Integer, Real, or Real Number with Units attributes with undefined attribute values instead of reporting an error. A zero is used for the undefined value. The attributes specified in a comma-separated list must be of Integer, Real, or Real Number with Units data types included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include an attribute, the roll-up calculation reports an error for an undefined value used for calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
Name
|
Description
|
Default Value
|
|---|---|---|
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowBooleanSummationWithANDOperation
|
When the property is defined and set, Multi-Level BOM Roll-up uses an AND operator for the specified Boolean attributes in the summation calculation. The Boolean attributes specified in a comma-separated list must be included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include a Boolean attribute, an OR operator is used in the summation calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
Name
|
Description
|
Default Value
|
|---|---|---|
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowBooleanSummationWithUndefinedValues
|
When the property is defined and set, Multi-Level BOM Roll-up allows roll-up summation calculation for the specified Boolean attributes with undefined attribute values instead of reporting an error. Unless overridden, the value of FALSE is used for the undefined value. The attributes specified in a comma-separated list must be Boolean attributes included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include a Boolean attribute, the roll-up calculation reports an error for an undefined value impacting the calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowBooleanSummationWithUndefinedValuesAsTrue
|
When the property is defined and set, Multi-Level BOM Roll-up overrides the default value, making the default value TRUE, used by roll-up summation calculation for the specified Boolean attributes with undefined attribute values. The attributes specified in a comma-separated list must be Boolean attributes included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowBooleanSummationWithUndefinedValues property.
When the property is not defined or does not include a Boolean attribute, the default value is unchanged.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|