Functional Area
|
Name
|
Status
|
Description
|
Default Value
|
|---|---|---|---|---|
|
Change Management
|
Staged Plan Execution
|
Enables the use of staged implementation plans for executing change tasks.
• Yes—When set to Yes, enables the author of a change task to plan and execute the implementation plan in defined stages.
• No—When set to No, the implementation plans of change tasks cannot be staged.
When enabled, the Stage column appears in the Implementation Plan table:
|
No
|
|
|
CAD Data Management
|
Skip CAD/Dynamic Document Attachments
|
New
|
Restricts the type of attachments copied onto the new CAD/Dynamic document. When using commonspace or workspace Revise and Save As actions, the preference specifies the attachments excluded from this action.
|
|
|
Windchill Search
|
Latest Version Search
|
Updated
|
Provides a general control over version search of objects.
• All — Returns all versions that match the specified search criteria
• Latest — Returns the latest version that matches the specified search criteria.
• Absolute Latest — Returns a result only if the recent most version matches the search criteria.
|
All
|
|
Windchill Workgroup Manager
|
Set CAD Component Name
|
New
|
Controls whether the CATIA V5 instance name is mapped to the component name in the CAD structure and used as the reference designator in the Windchill WTPart structure.
To set this preference in the Windchill Preference Management utility, click > .
• Yes (default)—Maps the instance name to Windchill and propagates it to the Reference Designator column in the Windchill Occurrences tab.
• No—Does not map the instance name to Windchill. The Reference Designator column remains blank.
|
Yes
|
|
Windchill Workgroup Manager
|
primary.monitor
|
New
|
When using multiple monitors, set this preference in the wgmclient.ini file to launch Windchill Workgroup Manager on a specific monitor. Specify a value from 1 to the number of monitors available.
|
0
|
|
Windchill Workgroup Manager
|
dpi.scale
|
New
|
When using multiple monitors, set this preference in the wgmclient.ini file to apply a specific DPI scale to the Windchill Workgroup Manager window across all monitors.
|
100
|
|
|
We are in the process of converting existing properties into new preferences. It is recommended that you set the values correctly for newly introduced preferences. As part of the setup, you should review the settings of the new configuration and reevaluate the default values of preferences.
|
|
Functional Area
|
Name
|
Status
|
Description
|
Default Value
|
|---|---|---|---|---|
|
Windchill Configuration Management
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes
|
Updated
|
When the property is defined and set, the Multi-Level BOM Roll-up action is enabled. The property value that is specified controls the attributes, using their internal names, available to the end users when performing the roll-up summation calculations for one or more roll-up eligible attributes on a bill of materials. The attributes specified in a comma-separated list must be of Integer, Real, Real Number with Units, or Boolean data types defined on a part.
This property is deprecated and will be terminated in a future Windchill release.
|
Not set
|
|
Windchill Configuration Management
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.ConfigurablePartUseDefinedValue
|
New
|
When the property is defined and set, Multi-Level BOM Roll-up uses the specified attribute value defined for configurable parts in the summation calculation. The attributes specified in a comma-separated list must be included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include an attribute, the attribute value defined for configurable parts is not included in the roll-up summation calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
Windchill Configuration Management
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.EndItemDoNotUseDefinedValue
|
New
|
When the property is defined and set, Multi-Level BOM Roll-up uses the specified attribute value defined for end items in the summation calculation. The attributes specified in a comma-separated list must be included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include an attribute, the attribute value defined for end items is not included in the roll-up summation calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
Windchill Configuration Management
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowNumericSummationWithPartialValues
|
New
|
When the property is defined and set, the Multi-Level BOM Roll-up allows roll-up summation calculation for the specified Integer, Real, or Real Number with Units attributes with undefined attribute values instead of reporting an error. A zero is used for the undefined value. The attributes specified in a comma-separated list must be of Integer, Real, or Real Number with Units data types included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include an attribute, the roll-up calculation reports an error for an undefined value used for calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
Windchill Configuration Management
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowBooleanSummationWithANDOperation
|
New
|
When the property is defined and set, Multi-Level BOM Roll-up uses an AND operator for the specified Boolean attributes in the summation calculation. The Boolean attributes specified in a comma-separated list must be included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include a Boolean attribute, an OR operator is used in the summation calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
Windchill Configuration Management
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowBooleanSummationWithUndefinedValues
|
New
|
When the property is defined and set, Multi-Level BOM Roll-up allows roll-up summation calculation for the specified Boolean attributes with undefined attribute values instead of reporting an error. Unless overridden, the value of FALSE is used for the undefined value. The attributes specified in a comma-separated list must be Boolean attributes included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes property.
When the property is not defined or does not include a Boolean attribute, the roll-up calculation reports an error for an undefined value impacting the calculation.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
Windchill Configuration Management
|
deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowBooleanSummationWithUndefinedValuesAsTrue
|
New
|
When the property is defined and set, Multi-Level BOM Roll-up overrides the default value, making the default value TRUE, used by roll-up summation calculation for the specified Boolean attributes with undefined attribute values. The attributes specified in a comma-separated list must be Boolean attributes included in the deprecated.com.ptc.windchill.enterprise.rollup.multilevelBOMRollupEligiblePartAttributes.AllowBooleanSummationWithUndefinedValues property.
When the property is not defined or does not include a Boolean attribute, the default value is unchanged.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|
|
Windchill Configuration Management
|
deprecated.com.ptc.windchill.enterprise.part.reports.hideNextGenerationBOMReports
|
New
|
When the property is not defined or is set to False, the BOM Reports option is available for a part structure in Reports.
When the property is set to True, the BOM Reports capability is not available and Reports provides only the list of classic BOM Reports.
This property is deprecated from this release and will be terminated in a future Windchill release.
|
Not set
|