Upload Preferences
Upload Preferences
The following table describes the preferences for the Upload action.
Preference
Values
Description
Ignore Legacy Parameters
<comma-separated list>
Specifies a list of legacy parameters to ignore during upload operation if corresponding attribute is not present in the type definition on server. This is a comma-separated list and is sensitive to spaces after the comma.
Initial Revision Parameter
<string>
Identifies the file property name that shows the initial revision to be used when uploading a file to Windchill. This revision is set on first upload and is further controlled by Windchill.
Naming Parameter
<string>
Specifies the CAD tool parameter to be used when generating a CAD document name upon initial upload
Numbering Parameter
<string>
Specifies the CAD tool parameter to be used when generating a CAD document number upon initial upload
Soft type Parameter
<string>
Identifies the file property name that shows the soft type to be used when uploading a file to Windchill. The default value is UPLOAD_SOFT_TYPE. This property is used to assign a specific soft type to a file or a template. Soft type will be set on first upload and will not change after that.
Drop File Extension From Name
Yes
No (default)
Specifies whether actions that create or rename a CAD document should drop the file extension in the system-generated CAD document name. The default value is No which means the file extension is included in the name.
* 
This preference is not applicable to the following authoring applications.
ECAD
CADDS 5
Drop File Extension From Number
Yes
No (default)
Specifies whether actions that create or rename a CAD document should drop the file extension in the system-generated CAD document number. The default value is No which means the file extension is included in the number.
* 
This preference is not applicable to the following authoring applications.
ECAD
CADDS 5
Use Current Attribute Mapping
<comma-separated list>
Allows the selective set of designated parameters to be mapped to Windchill attributes using the current attribute mapping definition instead of the mapping that was previously used. List the name of parameters, separated by , (comma). This option is applicable for parameters mapped to Windchill reusable attribute with type floating number with units only.
Use Explicit Mapping for Designated Parameter Creation
Yes
No (default)
This option controls the name of the designated parameter to be created in the file. If the attribute name and parameter name in the file are explicitly mapped, and if the corresponding parameter does not exist in the file, this option allows the user to control the name of the parameter to be created in the file. The default value is "No". Set to No, the name of the parameter is the same as Windchill attribute name. Set to Yes, the name of the parameter is based on the explicit attribute mapping.
¿Fue esto útil?