Keyword
|
Value or Description
|
---|---|
Directory
|
Specifies the fully qualified directory location of the converted data.
|
Documentnumber
|
Specifies the number of an existing WTDocument to which you associate the representation.
|
Documentversion
|
Specifies the version of the WTDocument to which you associate the representation.
|
Encoding
|
Specifies the character set encoding of the PVS file (if the PVS file has no J tag present). The default is to use the J tag-specified encoding or the encoding of the Windchill server.
|
Edzcreate
|
Specifies if a PVZ file is to be created. Can be set to true or false.
The default is false.
|
Ignoreonmerge
|
Adds a flag to children of the PVS file's root node to indicate that those children should be ignored when using this representation in a WTPart structure. For example, if the root WTPart includes a representation of the complete assembly, but you want to view the data from the individual WTParts when viewing a structure, use ignoreonmerge.
|
Includemarkups
|
Specifies if markups in the input data is stored with the representation in Windchill. Can be set to true or false.
The default is true.
|
Iteratepart
|
Specifies if an existing part is to be iterated. Can be set to true or false.
The default is false.
|
Partfolder
|
Specifies the folder in which the part is created.
|
Partlifecycle
|
Specifies the life cycle associated with the new part.
|
Partcontainer
|
Specifies the context (for example, Projects, Products, or Libraries) in which a new part is created. The folder and life cycle values are determined by the context and need not be specified.
You can specify the context as a name or parentname/name. For example, if the organization PTC contains a project proj1, you can specify partcontainer as proj1 or PTC/proj1 (to distinguish it from other projects called proj1 in other organizations).
|
Partname
|
Specifies the part name.
|
Partnumber
|
Specifies the part number of an existing part (the part number is created if it does not exist).
|
Partoid
|
Specifies the Windchill ID of an existing part.
|
Partteam
|
Specifies the team associated with the new part.
|
Partrevision
|
Specifies the part revision.
|
Repdefault
|
Specifies whether the representation is to be the default. Can be set to true or false.
The default is false.
|
Repdesc
|
Describes the representation to be created.
|
Repname
|
Specifies the name of the representation to be created.
|
Representtableoid
|
Specifies the Windchill ID of an existing representable.
|
Thumbnailcreate
|
Specifies whether a thumbnail is to be created. Can be set to true or false.
The default is false.
|
Ticketencoding
|
Specifies the character set encoding of the ticket file. If specified, this must be the first line in the ticket file. If not specified, the encoding of the Windchill server is assumed.
|
|
The file must end in <!>. Keywords are case-insensitive, as are true and false values.
|
|
For a large assembly, the loader task can be time-consuming, especially if server-side thumbnail generation is performed .
For information about server-side thumbnail installation, see Thumbnail Generator and Viewable Compression Utilities in the Windchill Installation and Configuration Guide (Руководство по установке и настройке Windchill).
For more information about Windchill Viewable Compression Utilities, refer to “Introduction to Windchill Viewable Compression Utilities” in the Creo View MCAD Adapter Installation and Configuration Guide (Руководство по установке и конфигурации Creo View MCAD Adapter).
|