Implicit Parameter-to-Attribute Mapping (CATIA V5)
Implicit mapping occurs when the authoring application parameter uses the exact syntax as its Windchill attribute. This makes the parameter publish automatically in the authoring application.
For example, a CAD document has a set of soft attributes that are published to the authoring application. From this set, use the soft attribute Name and map it to the NAME of the parameter in the authoring application. The soft-types that used in this case are:
EPMDocument
EPMMemberLink
EPMReferenceLink
If Name is the same by a case-sensitive evaluation, the two are implicitly mapped. Other parameters are not be added to the CAD document, unless they are explicitly mapped. For example, in the authoring application, if the administrator has created a soft attribute with the name, Cost, then the user must also create the soft attribute with the name Cost so it is implicitly mapped. If the authoring application user creates COST, it will not be mapped.
If the authoring application does not support case-sensitive parameter names, the name is treated in all uppercase characters. For example, if the authoring application treats Cost and COST the same, then Windchill receives and handles this attribute as COST. The Windchill soft attribute name must also be COST.
* 
Although the user may create a authoring application parameter called Cost, it is passed to Windchill as Cost. Therefore, ensure the authoring application parameter name is in all uppercase so that it is implicitly mapped in Windchill. Other properties are not added to the CAD document, unless they are explicitly mapped.
If a mapped parameter is inconsistent with its corresponding soft attribute, the following occurs.
Type
If the two are not the same type then a warning is given to the user upon upload; but upload continues. The value is not pushed to the CAD document.
Units
If the quantity of measure is different between the attribute and the parameter, then the CAD document receives an error upon upload. The user is notified to check in the CAD document.
Isto foi útil?