autoStart
|
• true—The SCIM subsystem starts automatically after a ThingWorx reboot.
• false—You must manually start the SCIM subsystem after a reboot.
|
enableSCIM
|
• true—The SCIM subsystem is enabled at run time within the ThingWorx web application.
• false—The SCIM subsystem is disabled at run time within the ThingWorx web application.
|
authScimOAuthClientId
|
Mandatory
The OAuth client ID configured for SCIM.
Use the value you provided in the CLIENT ID field in the Microsoft Entra ID application. To find this value, click your Enterprise application under the App registrations in Microsoft Entra ID and copy the Application (client) ID value.
|
issuer
|
Mandatory
The issuer configured for SCIM.
Use the issuer with the tenant ID of Microsoft Entra ID:
https://sts.windows.net/<tenantId>/
|
jwtPublicKeyUrl
|
Mandatory
This public key URL is required to verify the authenticity of the token.
To acquire the signing key data necessary to validate the signature of the token, open the following JSON document:
In the JSON document, find the jwks_uri parameter and copy the value to use here. For example:
https://login.microsoftonline.com/common/discovery/keys
|
authScimOAuthClientIdAttrName
|
Optional.
This is a Client ID verification. The validation compares the authScimOAuthClientIdAttrName value claim with the value of authScimOAuthClientId property.
For Microsoft Entra ID the value will usually be appid.
|