Installation > Performing an Upgrade > Upgrade from Integrity Modeler 8.2 or Earlier
Upgrade from Integrity Modeler 8.2 or Earlier
Upgrade from Integrity Modeler 8.2 or earlier
A direct upgrade from Integrity Modeler 8.2 or earlier is not supported. To upgrade to Integrity Modeler 9.2, follow these steps:
1. If you are running an earlier version, upgrade to Integrity Model 8.5, 8.4, or 8.3:
a. Backup datastores using the Save command in the Database Administrator.
b. Backup any customizations (including Publisher templates, DOORs or ILM synchronizer mappings, custom Reviews in Reviewer, custom Profiles, etc.)
c. If you previously separately installed Reviewer for use by 'Just me' (by choosing this option in the install wizard), or you do not know which option was chosen, uninstall Reviewer before upgrading.
d. For client/server installations, upgrade the server(s) first and then all the clients. A datastore may not be accessed by clients on different version of Artisan Studio or Integrity Modeler.
e. Install directly over your previous version by running IntegrityModeler8_5Setup.exe. Do not manually uninstall the older version first, it will be uninstalled during the upgrade process. This will ensure that all settings are retained after the upgrade and access rights (including Administration) to your existing datastores are retained. If you do uninstall and then reinstall you may not have rights to your existing datastores.
f. On the Custom Setup page of the Installation, ensure that all the components you would like installed after the upgrade are selected to be installed.
g. If you upgraded a server-only install from 6.1 , and had made manual changes to the WinPasswd and WinGroup files, these need to be migrated as follows:
a. Open a command prompt and type the following command (substitute paths as necessary if you have not used the install defaults):
c:
cd\Enabler\Server\Param
copy WinPasswd.bak WinPasswd
copy winGroup.bak WinGroup
ren users users.bak
ren groups goups.bak
cd..\bin
omsdiag migrateWinPasswd
h. Reboot computer.
2. Upgrade to Integrity Modeler 9.2. For more information, see Upgrade from Integrity Modeler 8.3 or Later.