Board (automation interface)
A node representing a board on the System Architecture Diagram.
ATTRIBUTES:
In addition to the common attributes
Base Address
An integer property describing the base address of the Board.
Access is read/write.
Description
A textual property that gives an overview of the dictionary item.
Access is read/write.
Number of Instances
A string describing the number of instances of this Board. A maximum of 100 characters.
Access is read/write.
ASSOCIATIONS:
In addition to the common associations
Relationship to Comments that are applied to the Board.
Multiplicity is 0+, access is read/write.
Relationship to Constraints that are applied to the Board.
Multiplicity is 0+, access is read/write.
A relationship with a Board Type Dictionary Item.
Multiplicity is 0-1, access is read/write.
Relationship to scoping Package. This association and the Subsystem association are mutually exclusive.
Multiplicity is 0-1, access is read/write.
A collection of Drops associated with one Board.
Multiplicity is 0+, Access is read/write.
Relationship to Comments that are owned by the Board.
Multiplicity is 0+, access is read/write.
Relationship to Constraints that are owned by the Board.
Multiplicity is 0+, access is read/write.
A collection of Packages associated with one Board. The board runs the software of the Packages.
Multiplicity is 0+, Access is read/write.
A collection of Point-to Point Connections with one Board as the destination.
Multiplicity is 0+, Access is read/write.
Note that you must use P2p Connection End, not Point to Point Connection End.
A collection of Point-to-Point Connections with one Board as the source.
Multiplicity is 0+, Access is read/write.
Note that you must use P2p Connection Start, not Point to Point Connection Start.
A relationship with a Subsystem item. This association and the Category/Package association are mutually exclusive.
Multiplicity is 0-1, access is read/write.
A collection of Tasks associated with one Board.
Multiplicity is 0+, access is read/write.
Was this helpful?