Error Messages
Unexpected error reading the project file.
Error Type:
Informational
 
Invalid extractor version. Please check your installation.
Error Type:
Warning
 
Possible Solution:
Check your installation.
 
Unable to open the selected project. Make sure that the correct version of Openness is installed.
Error Type:
Warning
 
Possible Solution:
Make sure that the correct version of Openness is installed.
 
Error initializing the Openness API. Please verify that all necessary components are installed.
Error Type:
Warning
 
Possible Cause:
Not all necessary components of Openness API are installed.
 
Possible Solution:
Please verify that all necessary components are installed.
 
Failed to open the project file. Please verify that the project can be opened by the version of TIA Portal installed on this system and that the project is not currently open in TIA Portal.
Error Type:
Warning
 
Possible Causes:
1. The version of TIA Portal installed on this system is not compatible with the project.
2. The project is currently open in TIA Portal.
 
Possible Solutions:
1. Verify that the project can be opened by the version of TIA Portal installed on this system.
2. Verify that the project is not currently open in TIA Portal.
 
A problem has been encountered extracting tags from the selected project. Please verify that the project is complete and has been successfully compiled.
Error Type:
Warning
 
Possible Causes:
The project is not complete nor successfully compiled.
 
Possible Solution:
Verify that the project is complete and has been successfully compiled.
 
Timed out waiting for the extractor to complete.
Error Type:
Warning
 
The selected project type is not currently supported.
Error Type:
Informational
 
Possible Solution:
Convert the project to one of the supported versions.
 
No extractors can be found on the system. Please check your installation.
Error Type:
Warning
 
Possible Cause:
There is an issue with the installation.
 
Possible Solution:
Check the installation.
 
Project load canceled.
Error Type:
Informational
 
Failed to export to file.
Error Type:
Informational
 
Possible Cause:
The selected file is in use or open in another application.
 
Possible Solution:
Close the selected file in any other application or instance.
 
Failed to start extractor process.
Error Type:
Informational
 
Unable to load project.
Error Type:
Informational
 
Unable to find help documentation. Please verify your installation.
Error Type:
Warning
 
Possible Cause:
There is an issue with the installation.
 
Possible Solution:
Check the installation.
 
Unable to access the Openness API. The current user is not a member of the Siemens TIA Openness group.
Error Type:
Warning
 
Possible Cause:
The current user is not a member of the Siemens TIA Openness group.
 
Possible Solution:
Add current user to the Siemens TIA Openness group.
 