Creo Expert Moldbase Extension > Options > About Ejector Bore Data
  
About Ejector Bore Data
When you place an ejector pin, a set of cutouts is automatically made in several plates. These holes and counterbores should comply with company-specific standards. The standard values are defined on the Ejector Bore Data tab of the EMX Options dialog box:
EJP_LOWER_B—Lower limit of the ejector pins nominal diameter.
EJP_UPPER_B—Upper limit of the ejector pins nominal diameter.
EJP_LL—Minimum length of the ejector pin guided section in the core-plate.
EJP_LD—Add this value to the guided bore diameter add-on (fit H7).
EJP_FD—Add this value to the diameter add-on of the counterbore in the core-plate.
EJP_BD—Add this value to the diameter add-on of all thru holes.
EJP_ND—Add this value to the diameter add-on for the smaller diameter in the head counterbore.
EJP_CD—Add this value to the head counterbore diameter assigned in the ejector pin dialog box.
EJP_CL—Add this value to the head-counterbore depth assigned in the ejector pin dialog box.
EJP_FL—Default length for Rotation fix-cutout (use absolute value or <x>*D for multiple nominal diameter).
EJP_FW—Default width for Rotation fix-cutout (use absolute value or <x>*D for multiple nominal diameter).