Replacement in Object TOOLKIT: |

ProMdlCombStateCreate | |
( ProSolid p_solid /* (In) Solid. */ ProName new_name /* (In) Name of the new state. */ ProModelitem* ref_arr /* (In) ProArray of references. Must be non empty array. See ProCombstateDataGet for possible types of items in this array. The PRO_XSEC item may represent either a valid ProXsec handle or a zone feature. Use ProModelitemIsZone to check it and, if it returns TRUE, change the item type to PRO_FEATURE and use ProFeatureZoneGet instead. Omit a reference for 'NO STATE', where comb state activation will not affect this aspect, and use id PRO_COMBSTATE_REF_MRU for Most Recently Used. */ ProCrossecClipOpt clip_opt /* (In) Cross section clip option. Not used if PRO_XSEC reference is not passed. */ ProBool is_expld /* (In) Is state exploded or not. Not relevant in Part. */ ProCombstate* cs_item /* (Out) Created combined state item. Allowed to be NULL. */ ) |

Combined state created. | |
Invalid solid or name (including that combined state with such name exists. Reference array is NULL or it's size is zero. | |
Invalid references. Possible errors: | |
- The type of one of the references is not valid. | |
- Reference of some type appears twice or more. | |
- Id and type of a reference don't match. |