Tool Motion — Ramp Approach
The compound element PRO_E_TOOL_MTN is a member of PRO_E_TOOL_MTN_ARR array and is documented in the header file ProMfgElemToolMtnRampAppr.h, and is shown in the following figure.
Figure 205. Element tree for PRO_E_TOOL_MTN element
The following table lists the contents of PRO_E_TOOL_MTN element.
Element ID
Data Type
Description
PRO_E_TOOL_MTN_TYPE
PRO_VALUE_TYPE_INT
Mandatory element. Species the tool motion type. The valid value for this element is PRO_TM_TYPE_RAMP_APPROACH.
PRO_E_TOOL_MTN_FEED_TYPE
PRO_VALUE_TYPE_INT
Optional element. Specifies the type of feed for the tool motion using the enumerated data type ProToolMtnFeedType. The valid value for this element are:
PRO_TM_FEED_FREE—Specifies a free feed type. Free feed specifies the rate at which the tool moves in the transverse motion, that is, the non-cutting motion.
PRO_TM_FEED_CUT—Specifies a cut feed type. Cut feed specifies the rate at which the tool moves into the workpiece.
PRO_TM_FEED_PLUNGE—Specifies a plunge feed type. Plunge feed specifies the rate at which the tool approaches and plunges into the workpiece.
PRO_TM_FEED_APPROACH—Specifies an approach feed type. Approach feed specifies the rate at which the tool approaches the workpiece.
PRO_E_MFG_PARAM_ARR
Array
Mandatory element. Specifies an array of manufacturing parameters. Elements that define the ramp exit motion are:
EXIT_DIST
EXIT_ANGLE
RAMP_ANGLE
See the Creo NC help for more information on manufacturing parameters. The element tree for the manufacturing parameter is defined in the header file ProMfgElemParam.h. For more information, refer to the section Manufacturing Parameters for more information on the element tree.
PRO_E_MFG_APPR_EXIT_DIR
PRO_VALUE_TYPE_INT
Mandatory element. Specifies the direction for the ramp approach type of tool exit. The direction is defined by the enumerated data type ProTmSideDir in ProMfgOptions.h. The valid values for this element are:
PRO_TM_DIR_RIGHT_SIDE
PRO_TM_DIR_LEFT_SIDE