Action
|
Condition
|
---|---|
SET
|
Sets the specified value for the specified pin parameter when the other columns for that line in the table are TRUE.
|
MATCH
|
Matches the value in the table to the value of the parameter for all conductors routed to the pin. The value must be the same for all conductors routed to the pin.
|
MATCH_SPEC
|
Matches the value in the table to the value of the parameter in conductors. The value must be the same for all conductors with this parameter.
|
MATCH_ANY
|
Matches the value in the table to the value of the parameter in conductors. The parameter must exist and its value must be the same for at least one conductor.
|
MATCH_ONE
|
Matches the value in the table to the value of the parameter in conductors. The value must be the same for one conductor. The same conductor must also match all x_ONE conditions in the terminator table.
|
MATCH_PRE2000I
|
Matches the value in the table to the value of the parameter for a single conductor routed to the pin. This condition applies only to terminator tables from earlier versions of Pro/ENGINEER Diagram.
|
MIN
|
Searches for a parameter value greater than the table value for all conductors with this parameter routed to or from the pin.
|
MIN_SPEC
|
Searches for a parameter value greater or equal to the table value for all conductors with this parameter.
|
MIN_ANY
|
Searches for a parameter value for at least one conductor that is greater than or equal to the table value.
|
MIN_ONE
|
Searches for a parameter value greater than or equal to the table value for one conductor. In addition the same conductor must match all x_ONE conditions in the terminator table.
|
MAX
|
Searches for a parameter value less than the table value for all wires/conductors routed to the same pin.
|
MAX_SPEC
|
Searches for a parameter value less than the table value in all conductors with this parameter.
|
MAX_ANY
|
Searches for a parameter value less than the table value for at least one conductor.
|
MAX_ONE
|
Searches for a parameter value less than the terminator table value. A single conductor must match all x_ONE conditions in the terminator table.
|
MIN_SUM
|
Calculates the sum of the values for the specified parameters from all items applied to the pin. It must be greater than or equal to this value.
|
MAX_SUM
|
Calculates the sum of the values for the specified parameters from all items applied to the pin. It must be less than this value.
|
|
When a _SPEC, _ANY,_ONE, or _PRE2000I action is applied to a CONN or PIN, it is the same as using the MATCH, MIN, or MAX action. An action can search for a parameter value for only one PIN or CONN.
|