Piping > Setting Up Piping Library > Piping Specification Database > Master Catalog (MCAT) Files > Migrating Piping Data from Legacy PTD Files to CSV Format
  
Migrating Piping Data from Legacy PTD Files to CSV Format
You can convert the master catalog files from the PTD format to the CSV format by importing them into an editor such as Microsoft Excel. The converted files need some modifications before they are ready to use. Refer the following sections for more details on converting each type of file:
Piping Master Catalog Directory file
Bend file
Bend Machine file
Bend Spring Back and Elongation file
Miter file
Pipe Master Catalog file
Insulation file
Fitting file
Bolt Nut Selection file
End Compatibility file
Combined Size Code file
Converting Legacy Piping Master Catalog Directory File to CSV Format
Refer the file at <Creo load point>/text/piping_data/master_catalog as an example. The following table provides details for consolidating the Piping MCAT Directory PTD files to a single csv file.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
piping_mcat_dir.ptd
piping_mcat_dir.csv
piping_mcat_dir_file
Yes
Yes
Convert the Piping Master Catalog Directory PTD file to the CSV format and delete the following columns:
PIPE_OD_FILE
PIPE_THK_FILE
BOLT_NUT_CODE
Converting Legacy Bend files to CSV Format
Refer the bend file at <Creo load point>/text/piping_data/master_catalog/bend as an example. The following table provides details for consolidating the Bend PTD files to a single csv file.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
bend_steel.ptd
bend_steel.csv
piping_mcat_dir_file
Yes
Yes
piping_units_system_dic_file.ptd
units_system_dic_file
Yes
No
Refer the color coding in the following image for mapping contents from the PTD files to the CSV file:
Converting Legacy Bend Machine File to CSV Format
Refer the bend machine file at <Creo load point>/text/piping_data/master_catalog/bend_machine as an example. The following table provides details for consolidating the bend machine PTD files to a single csv file.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
bend_machine.ptd
bend_machine.csv
piping_mcat_dir_file
Yes
Yes
piping_units_system_dic_file.ptd
units_system_dic_file
Yes
No
Refer the color coding in the following image for mapping contents from the PTD files to the CSV file:
Converting Legacy Bend Spring Back and Elongation File to CSV Format
Refer the bend spring back and elongation file at <Creo load point>/text/piping_data/master_catalog/bend_machine as an example. The following table provides details for consolidating the bend machine PTD files to a single csv file.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
bend_springback_elong_steel.ptd
bend_springback_elong_steel.csv
piping_mcat_dir_file
Yes
Yes
piping_units_system_dic_file.ptd
units_system_dic_file
Yes
No
Refer the color coding in the following image for mapping contents from the PTD files to the CSV file:
Converting Legacy Miter File to CSV Format
Refer the miter file at <Creo load point>/text/piping_data/master_catalog/miter as an example. The following table provides details for consolidating the bend machine PTD files to a single csv file.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
miter_steel.ptd
miter_steel.csv
piping_mcat_dir_file
Yes
Yes
piping_units_system_dic_file.ptd
units_system_dic_file
Yes
No
Refer the color coding in the following image for mapping contents from the PTD files to the CSV file:
Converting Legacy Pipe Mater Catalog Files to CSV Format
Refer the Pipe MCAT file at <Creo load point>/text/piping_data/master_catalog/pipe as an example. The following table provides details for consolidating the Pipe Master Catalog PTD files to a single csv file.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
pipe_steel.ptd
pipe_steel.csv
piping_mcat_dir_file
Yes
Yes
piping_units_system_dic_file.ptd
units_system_dic_file
Yes
No
piping_material.ptd
piping_material_file
Yes
No
piping_manufacture_dir.ptd
piping_manufact_dir_file
Yes
No
od_steel.ptd
piping_mcat_dir_file
Yes
Yes
thk_steel.ptd
piping_mcat_dir_file
Yes
Yes
Refer the color coding in the following image for mapping contents from the PTD files to the CSV file:
Converting Legacy Insulation Files to CSV Format
Refer the Insulation file at <Creo load point>/text/piping_data/master_catalog/insulation as an example. The following table provides details for consolidating the Insulation PTD files to a single csv file.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
exhaust.ptd
exhaust.csv
piping_mcat_dir_file
Yes
Yes
piping_units_system_dic_file.ptd
units_system_dic_file
Yes
No
piping_material.ptd
piping_material_file
Yes
No
Refer the color coding in the following image for mapping contents from the PTD files to the CSV file:
Converting Legacy Fitting Master Catalog Files to CSV Format
Refer the Insulation file at <Creo load point>/text/piping_data/master_catalog/insulation as an example. The following table provides details for consolidating the Insulation PTD files to a single csv file.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
coupling_sw_steel.ptd
coupling_sw_steel.csv
piping_mcat_dir_file
Yes
Yes
piping_mcat_dir.ptd
piping_mcat_dir_file
Yes
Yes
piping_material.ptd
piping_material_file
Yes
No
Refer the color coding in the following image for mapping contents from the PTD files to the CSV file:
Converting Legacy Bolt Nut Selection File to CSV Format
Refer the bolt nut selection file at <Creo load point>/text/piping_data/master_catalog as an example. The following table provides details for consolidating the Insulation PTD files to a single csv file.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
piping_bolt_nut_select.ptd
piping_bolt_nut_select.csv
piping_bolt_nut_select_file
Yes
Yes
bolt_nut_mcat.ptd
Refer the color coding in the following image for mapping contents from the PTD files to the CSV file:
Converting Legacy End Compatibility File to CSV Format
Save the end compatibility file at <Creo load point>/text/piping_data/master_catalog as a CSV file to convert it to the csv format.
Legacy PTD files
New CSV File
Required Configuration option
PTD
CSV
piping_end_compatibility.ptd
piping_end_compatibility.csv
piping_end_compatibility
Yes
Yes
Converting Combined Size Code File to CSV Format
Save the combined size code file at <Creo load point>/text/piping_data/master_catalog as a CSV file to convert it to the csv format.