Piping > Design Rule Checking and Piping (Report) Information > Spec-Driven Pipeline Reporting > Pipeline Network Report > Errors in the Pipeline Network Report
  
Errors in the Pipeline Network Report
In addition to information about the pipeline connections and the existing pipe objects, the Pipeline Network report also displays the following types of warning messages:
Missing gaskets and flanges for fittings in the upstream or downstream direction
Missing corner fittings in the case of a pipe vertex modeled as a corner fitting
Mismatch in end types for a fitting in the upstream or downstream direction
Violations in the design rule about the minimum clamp length at the start or end of a pipe piece
Violations in the design rule about the minimum or maximum pipe segment length
Mismatch in any of the pipeline label formats
Extensions that are nor connected with the pipeline network
Mismatch in sizes between free port and its connected pipeline
A piping model is shown in the next figure:
The 150A-MS-STEAM-OP2 pipeline is missing an upstream flange and gasket on the gate valve and elbow between the last and last but one pipe segments.
These errors are reported as shown: