Piping > Design Rule Checking and Piping (Report) Information > Design Rules Checking > Displaying Segment Violations
  
Displaying Segment Violations
Segment violation types are displayed under Design Rules Tree in the Design Rules Check dialog box as follows:
Min Segment Length—Displays violation results if you create a pipe segment with a length shorter than the minimum segment length.
Max Segment Length—Displays violation results if you create a pipe segment with a length greater than the maximum segment length.
The violation results are displayed in the following columns under Violation Details when you click Min Segment Length or Max Segment Length:
Stockno—The stock number of the pipe.
Current—The current segment length.
Required—The required minimum or maximum segment length.
Total Segment Length—Displays violation results if you create pipe segments of a pipe in the active assembly where the pipe segments have length greater than the total pipe length. The violation results are displayed in the following columns under Violation Details:
Stockno—The stock number of the pipe.
Current—The total segment length.
Required—The required total segment length.