Mold Design and Casting > Verifying Models > To Perform a Mold Analysis on Waterlines
  
To Perform a Mold Analysis on Waterlines
1. On the Mold or Cast tab, click Analysis > Mold Analysis. The Mold Analysis dialog box opens.
2. Specify the part on which you want to perform the analysis. On the Waterline menu, select All Waterlines, Select Waterlines, or Select Surfaces. Type a value defining the minimum clearance for the waterlines in the Minimum Clearance box.
3. Click Computation Settings and under Resolution, the following are available:
—Define the resolution by setting the density of points. You can use the slider to increase the quality of the analysis.
—Define the resolution by setting the exact number of points to be used for conducting the analysis.
 —Define the resolution by setting the distance between two adjacent points in the model units.
Result refinement—Increases the accuracy of the results for the analysis.
Dynamic Update—The results are updated automatically as you change the value of the parameters.
4. Click Compute to perform the analysis and Display to set the display options for the analysis.
5. To save the analysis, click Saved Analysis, type a name for the analysis to be saved, and click .