DA_MODIFY_HEATFLOW_FACE modifies the heatflow on a face.
-->DA_MODIFY_HEATFLOW_FACE--+
|
+---------------------------+
|
+----+--+--(:LBC)----------|SELECT S_FERRUM_HEAT_FLOW|--(*1*)--+-->
| | |
| +--(:STUDY)--------|SELECT S_FERRUM_STUDY|-------------+
| | |
| +--(:NAME)---------|string|----------------------------+
| | |
| +--(:REF-ELEM)-----|face|------------------------------+
^ | |
| +--(:VALUE)--------|heatflow per unit area|------------+
| | |
| +--(:TOTAL-VALUE)--|total heatflow|--------------------+
| |
+-------<-----------<----------<---------<-----------<----+
The following options are available.
-
:LBC
- specifies the LBC associated with the heatflow.
-
:STUDY
- specifies the name of the associated study for the heatflow.
-
:NAME
- specifies the name of the heatflow to modify.
-
:REF-ELEM
- specifies the part element with the heatflow to modify.
-
:VALUE
- specifies the value for the heatflow.
-
:TOTAL-VALUE
- specifies the total value for the heatflow.
Use this action when modifying heatflows on a part in Design Integrity.