SET_DEFAULT_PART_RESOLUTION terminate action

SET_DEFAULT_PART_RESOLUTION sets the part resolution (accuracy) for new parts created in OneSpace Designer. The default resolution is set at 1.0E-6 mm (or 0.000001 mm).

Syntax


-->(SET_DEFAULT_PART_RESOLUTION)----|accuracy|--->

Options

This action has no options.

When to use

Use this action to set the geometric resolution (accuracy) of a part that you want to create in OneSpace Designer. You can choose an accuracy between 1.0E-2 and 1.0E-6, with 1.0E-6 being the maximum accuracy. The units are in millimeters regardless of the units setting.

Example

The following parameter sequence sets the resolution of the next part to be created to 1.0E-4 (0.0001 mm).

SET_DEFAULT_PART_RESOLUTION .0001

See also

SET_PART_RESOLUTION terminate action