DA_THERMAL_DERIVED_UNITS enables modification of specific individual thermal units of measure for the session environment.
-->DA_THERMAL_DERIVED_UNITS-----+
|
+-------------------------------+
|
+---+---+--(:DA_HEATFLOW)---------+--(:JOULE_PER_SECOND)---------------------------+---+-->
| | | | |
| | +--(:KILOJOULE_PER_SECOND)-----------------------+ |
| | | | |
| | +--(:CAL_PER_SECOND)-----------------------------+ |
| | | | |
| | +--(:KILOCAL_PER_SECOND)-------------------------+ |
| | | | |
| | +--(:BTU_PER_SECOND)-----------------------------+ |
| | | | |
| | +--(:FOOT_POUNDFORCE_PER_SECOND)-----------------+ |
| | | | |
| | +--(:INCH_POUNDFORCE_PER_SECOND)-----------------+ |
| | | | |
^ | +--(:DERIVED)------------------------------------+ |
| | |
| +--(:DA_HEATFLOW_FACTOR)-----|number|------------------------------------------+
| | |
| +--(:DA_HEATFLUX)---------+--(:WATT_PER_M2)--------------------------------+---+
| | | | |
| | +--(:WATT_PER_MILLIMETER2)-----------------------+ |
| | | | |
| | +--(:MILLIWATT_PER_M2)---------------------------+ |
| | | | |
| | +--(:KILOWATT_PER_M2)----------------------------+ |
| | | | |
| | +--(:FOOT_POUNDFORCE_PER_SECOND_FOOT2)-----------+ |
| | | | |
| | +--(:INCH_POUNDFORCE_PER_SECOND_INCH2)-----------+ |
| | | | |
| | +--(:DERIVED)------------------------------------+ |
| | |
| +--(:DA_HEATFLUX_FACTOR)-----|number|------------------------------------------+
^ | |
| +--(:DA_THERMCOND)--------+--(:WATT_PER_M_KELVIN)--------------------------+---+
| | | | |
| | +--(:KILOWATT_PER_M_KELVIN)----------------------+ |
| | | | |
| | +--(:BTU_PER_FOOT_HOUR_FAHRENHEIT)---------------+ |
| | | | |
| | +--(:FOOT_POUNDFORCE_PER_SECOND_FOOT_FAHRENHEIT)-+ |
| | | | |
| | +--(:INCH_POUNDFORCE_PER_SECOND_INCH_FAHRENHEIT)-+ |
| | | | |
| | +--(:DERIVED)------------------------------------+ |
| | |
| +--(:DA_THERMCOND_FACTOR)----|number|------------------------------------------+
| | |
| +--(:DA_SPECIFIC-HEAT)----+--(:JOULE_PER_KILOGRAM_KELVIN)------------------+---+
^ | | | |
| | +--(:BTU_PER_POUND_FAHRENHEIT)-------------------+ |
| | | | |
| | +--(:DERIVED)------------------------------------+ |
| | |
| +--(:DA_SPECIFIC_HEAT_FACTOR)---|number|---------------------------------------|
| | |
| +--(:DA_FILMCOEFF)--------+--(:WATT_PER_M2_KELVIN)-------------------------+---|
| | | | |
| | +--(:WATT_PER_MILLIMETER2_KELVIN)----------------+ |
| | | | |
| | +--(:KILOWATT_PER_M2_KELVIN)---------------------+ |
| | | | |
| | +--(:BTU_PER_FOOT2_HOUR_FAHRENHEIT)--------------+ |
| | | | |
| | +--(:FOOT_POUNDFORCE_PER_SECOND_FOOT2_FAHRENHEIT)+ |
| | | | |
^ | +--(:INCH_POUNDFORCE_PER_SECOND_INCH2_FAHRENHEIT)+ |
| | | | |
| | +--(:DERIVED)------------------------------------+ |
| | |
| +--(:DA_FILMCOEFF_FACTOR)----|number|------------------------------------------+
| |
+------------<---------<-------<-----------<------------<------------<-------------+
The options are describe the standard thermal analysis units and are self-explanatory.
Use this action when modifying the session environment in Design Integrity.