DA_PP_SYMBOLS_SET allows modification of the display options when symbol display is selected.
-->(DA_PP_SYMBOLS_SET)---+-----(:DA_SCALE_METHOD)-------+--(:PERCENT_SCALE)--+---+-->
| | | |
| +--(:FACTOR_SCALE)---+ |
| | | |
| +--(:FIXED_SCALE)----+ |
| |
+-----(:DA_SCALE_PERCENT)---------|number|--------------+
| |
+-----(:DA_SCALE_FACTOR)----------|number|--------------+
| |
+-----(:DA_FIXED_VALUE)-----------|number|--------------+
| |
+-----(:DA_SYMBOL_COLOR)-------+--(:BLUE)-----+---------+
| | | |
| +--(:GREEN)----+ |
| | | |
| +--(:LT_BLUE)--+ |
| | | |
| +--(:RED)------+ |
| | | |
| +--(:MAGENTA)--+ |
| | | |
| +--(:YELLOW)---+ |
| | | |
| +--(:BROWN)----+ |
| | | |
| +--(:GRAY)-----+ |
| |
+-----(:DA_SYMBOL_LOCATION)----+--(:AT_NODES)-------+---+
| | | |
| +--(:ELEM_CENTROID)--+ |
| | | |
| +--(:ELEM_FACE)------+ |
| |
+-----(:DA_UPDATE_DISPLAY)------------------------------+
| |
+-------<-----------<----------<---------<-----------<--+
The following options are available to configure the symbol display.
-
:DA_SCALE_METHOD - enables scale method selection.
-
:FACTOR_SCALE - enables specification of a multiplication factor with DA_SCALE_FACTOR.
-
:PERCENT_SCALE - enables specification of a percentage value of the total model size for calculating the magnification factor with :DA_SCALE_PERCENT.
-
:FIXED_SCALE - enables selection of a fixed length for all symbols with :DA_FIXED_VALUE.
-
:DA_SCALE_FACTOR - specifies a multiplication factor.
-
:DA_SCALE_PERCENT - specifies a percentage value for calculating scale factor.
-
:DA_FIXED_VALUE - specifies a fixed symbol length for display.
-
:DA_SYMBOL_COLOR - enables specification of the symbol display color.
-
:DA_SYMBOL_LOCATION - enables specification of a symbol positioning option.
-
:AT_NODES - selects symbols positioned at element nodes.
-
:ELEM_CENTROID - selects symbols positioned at element centroids.
-
:ELEM_FACE - selects symbols positioned at element faces.
-
:DA_UPDATE_DISPLAY - updates the results window according to the selected symbol display options.
Use this action when setting symbol display options for results in Design Integrity.
DA_PP_DEFORMED_SET terminate action,
DA_PP_CONTOUR_SET terminate action
DA_PP_RESULTS terminate action