DA_ACCELERATION applies an acceleration to a part.
-->DA_ACCELERATION--+
|
+-------------------+
|
+---+--+--(:STUDY)------|SELECT S_FERRUM_STUDY|-------------+-->
| | |
| +--(:NAME)-------|string|----------------------------+
| | |
| +--(:VALUE)------|acceleration|----------------------+
| | |
| +--(:COORD1)-----|acceleration|----------------------+
^ | |
| +--(:COORD2)-----|acceleration|----------------------+
| | |
| +--(:COORD3)-----|acceleration|----------------------+
| | |
| +--(:DIRECTION)--|MEASURE_DIR_3D_SA|-----------------+
| | |
| | +--(:GLOBAL)--------+ |
^ | | | |
| +--(:DA_COORD_SYSTEM)--+--(:LOCAL)---------+---------+
| | |
| +--(:SEL-CS)-----|select S_WORKPLANE|----------------+
| |
+-------<-----------<----------<---------<-----------<--+
The following options are available to configure and perform a finite element analysis of a part.
-
:STUDY - specifies the associated study for the acceleration.
-
:NAME - specifies the name of the acceleration to apply.
-
:VALUE - specifies an acceleration value to apply to the part.
-
:COORD1 - specifies the acceleration value acting on the edge along the first axis.
-
:COORD2 - specifies the acceleration value acting on the edge along the second axis.
-
:COORD3 - specifies the acceleration value acting on the edge along the third axis
-
:DIRECTION - enables specification of the direction of the force.
-
:GLOBAL - selects the global coordinate system.
-
:DA_COORD_SYSTEM - enables specification of the referential coordinate system.
-
:LOCAL - selects a local coordinate system.
-
:SEL-CS - specifies the reference workplane for the local and cylindrical coordinate systems.
Use this action when applying acceleration forces on a part with Design Integrity.