Option
|
Description
|
xml
|
Set the path to the input interference query file (mandatory).
pview_batch.exe -xml=<xml path>
For example,
pview_batch.exe -xml=D:\temp\batch_clash.xml
|
hidden_geom
|
Determines whether to include hidden geometry layers in the interference calculation (optional). If no value is stated, then hidden geometry layers are included in the interference calculation according to their default state.
pview_batch.exe -xml=<xml path> -hidden_geom=<all | default>
For example,
pview_batch.exe -xml=clash.xml -hidden_geom=all
|
hidden_parts
|
Determines whether to include hidden by default parts in the interference calculation (optional). If no value is stated, then hidden parts are not included.
pview_batch.exe -xml=<xml path> -hidden_parts=<all | default>
For example,
pview_batch.exe -xml=clash.xml -hidden_parts=all
|
ignore_surfaces
|
Determines whether to include non-solid geometries in the interference calculation (optional). If no value is stated, then non-solid geometries are included in the calculation.
pview_batch.exe -xml=<xml path> -ignore_
surfaces=<true | false> For example,
pview_batch.exe -xml=clash.xml -ignore_
surfaces=false Default value is false.
|