Configuring the Adapter Installation
This procedure applies to Windows only. To configure an adapter on Linux, see
Manual Steps for Adding Publishing to ECAD Tools.
A configuration utility is created for each Creo View ECAD Adapter that you install. This utility opens a dialog box where you can configure each adapter. The configuration consists of two parts:
• Parameters—Locates the correct version of the ECAD tool to start in publishing mode. The information about your ECAD tool appears automatically in the configuration dialog box.
• Components—Creates scripts for one or more of the publishing methods and sets the server location for server-controlled publishing.
Use an existing configuration or set a new one, as described in the steps below.
1. Browse to <installation_directory>\bin and double-click the configuration utility (<adapter>_config.exe) for your adapter. The configuration dialog box opens with the parameters for the ECAD tool. To set a new configuration, skip to step 3.
2. To use an Existing Configuration, perform these steps:
a. Next to the
Setup Directory box, click
. The
Select an Existing Setup Directory dialog box opens.
b. Browse to your configuration and click OK. The settings appear in the configuration dialog box.
c. Click Setup. The installation is configured.
3. Under Parameters, accept or change the parameters for the tools:
◦ Client/Server Version—Select the client or server version.
◦ Setup Directory—Browse to the adapter’s directory.
◦ Directory—Browse to the ECAD tool’s directory.
◦ Version—Select Auto-detect or a version number for the ECAD tool.
4. Under Components, create one or more publishing methods:
◦ Publish—Interactive
◦ Batch—Command-line
◦ Worker—Server-controlled
5. If you select the worker option, type the visualization server’s details in the boxes:
◦ Server Host
◦ Server Port
| To verify the details, click Test Server. |
6. Click Setup. The adapter installation is configured.