Example: Formatting a Wiring Report
1. Click > . The Format report dialog box opens.
2. Select the following options on the General tab:
◦ Properties as Report Type
◦ Criteria as Search Source
◦ Wiring as Diagram Type
◦ Fiber under Class
3. Click the Column tab, then click Add <Label> Column.
4. Enter Name as the Column Heading and name as the Parameter Format.
5. Repeat steps 3 and 4 and add the following label columns:
Column Heading | Parameter Format |
From Comp | [report_from_to(from,full_name,component)] |
From Port | [report_from_to(from,name,port)] |
To Comp | [report_from_to(to,full_name,component)] |
To Port | [report_from_to(to,name,port)] |
6. Click
. The generated report displays all design wires.