Displaying Bend Violations
Bend violation types are displayed under Design Rules Tree in the Design Rules Check dialog box as follows:
• Max Bend Numbers—Displays violation results if you create bends on a pipe segment greater than the specified maximum bend number value.
• Start Clamp Length—Displays violation results if you create a pipe segment with its start clamp length less than the specified value.
• Middle Clamp Length—Displays violation results if you create a pipe segment with its middle clamp length less than the specified value.
• End Clamp Length—Displays violation results if you create a pipe segment with its end clamp length less than the specified value.
• Min Bend Radius—Displays violation results if you create a pipe bend with its radius less than the specified value.
• Max Bend Radius—Displays violation results if you create a pipe bend with its radius greater than the specified value.
• Min Bend Angle—Displays violation results if you create a pipe bend with its angle less than the specified value.
• Max Bend Angle—Displays violation results if you create a pipe bend with its angle greater than the specified value.
In all the previous cases, the violation results are displayed in the following columns under Violation Details:
• Stockno—The stock number of the pipe.
• Line Stock—The name of the line stock.
• Current—The current bend number, start clamp length, middle clamp length, end clamp length, bend radius, or the bend angle.
• Required—The required bend number, start clamp length, middle clamp length, end clamp length, minimum bend radius, maximum bend radius, minimum bend angle, or the maximum bend angle.