Piping > Design Rule Checking and Piping (Report) Information > Design Rules Checking > Displaying Bend Violations
  
Displaying Bend Violations
Bend violation types are displayed under Design Rules Tree in the Design Rules Check dialog box as follows:
Max Bend Numbers—Displays violation results if you create bends on a pipe segment greater than the specified maximum bend number value.
Start Clamp Length—Displays violation results if you create a pipe segment with its start clamp length less than the specified value.
Middle Clamp Length—Displays violation results if you create a pipe segment with its middle clamp length less than the specified value.
End Clamp Length—Displays violation results if you create a pipe segment with its end clamp length less than the specified value.
Min Bend Radius—Displays violation results if you create a pipe bend with its radius less than the specified value.
Max Bend Radius—Displays violation results if you create a pipe bend with its radius greater than the specified value.
Min Bend Angle—Displays violation results if you create a pipe bend with its angle less than the specified value.
Max Bend Angle—Displays violation results if you create a pipe bend with its angle greater than the specified value.
In all the previous cases, the violation results are displayed in the following columns under Violation Details:
Stockno—The stock number of the pipe.
Line Stock—The name of the line stock.
Current—The current bend number, start clamp length, middle clamp length, end clamp length, bend radius, or the bend angle.
Required—The required bend number, start clamp length, middle clamp length, end clamp length, minimum bend radius, maximum bend radius, minimum bend angle, or the maximum bend angle.