Accessing the Designated Report Parameters in a Drawing
When you access the designated pipeline report parameters to use in assembly drawing tables, remember the following points:
• Information about designated reports is stored in the piping assembly. You access this information by using the table repeat region functionality in Drawing mode.
• To create a piping report in Drawing, make sure that you set the repeat region attribute to Recursive.
• To create a report that contains only piping information in the top-level assembly, set the Recursive attribute in the repeat region and add the filter [&rpt.level==1].
• Use the report parameters or the Report Symbol dialog box to set the values in the table cells.
• You cannot use report parameters that contain more than 32 characters in report relations, for example, as filters to determine what is displayed in a table.
For more information, search the Detailed Drawings functional area of the Creo Parametric Help Center.