Part Modeling > Resolving Regeneration Failures > Missing References > To Display Missing References from the Troubleshooter Dialog Box
  
To Display Missing References from the Troubleshooter Dialog Box
Before a possible feature failure, you must set up for the display of the missing references.
1. Right-click the failed feature in the Model Tree and choose Edit Definition. The feature creation tab opens.
2. Click the tab on which the feature references are listed.
3. Right-click the missing reference in the reference collector and choose What’s wrong. The Troubleshooter dialog box opens.
4. Perform any of the following actions:
To show a backup copy of the missing reference in the graphics window, select the missing reference.
To open a window of information about the reference, right-click the missing reference and choose Information.