Model-Based Definition > Model-Based Definition > Creating Various Annotation Types > Tolerances > Working with Dimensional Tolerances > Dimensional Tolerance Basics > Controlling the Display of Dimension Tolerances
  
Controlling the Display of Dimension Tolerances
Control the display of dimension tolerances by setting configuration options and tolerance values. Dimension tolerance values are displayed as one of the following:
nominal—Without tolerance
limits—Upper and lower limits
plusminus—Upper and lower tolerance
plusminussym—Nominal with single tolerance
plusminussym_super—Same as plusminussym. However, displays the plus-minus tolerance value at the half-way point of the dimension text extending upwards.
The order by which you set the configuration options to display dimensional tolerances is:
Action
Configuration Option
1. Display tolerance
tol_display to yes
2. Set default type of tolerance display
Detail option default_tolerance_mode to nominal, limits, plusminus, plusminussym, or plusminussym_super
3. Set display to 1000
display_tol_by_1000 to yes
4. View tolerance values in 2D (Drawing mode only)
display_dwg_tol_tags to yes
 
* Creo Parametric can multiply a tolerance value for nonangular dimensions by 1000. The tolerance value is displayed in the graphics area (only) as x, but is interpreted by Creo Parametric0.00x.