About General Parameters
The following tables lists the general welding parameters available in Welding. The configuration option pro_unit_length drives the default values.
* 
The default parameter values are followed by an asterisk (*).
You must substitute positive user-specific values for any negative default parameter value.
Parameters Available—All Welding Standards
Parameter Name
Value
Definition
BACK_SIZE_OPT
NO*
YES
Enables defining the size of the back weld
BACK_SIZE_VAL
NO*
YES
Enables entering the back weld size value
BACK_TYPE
NONE*
BACKING
BACK_WELD
Weld back type
BACKING
REMOVABLE_STRIP*
PERMANENT_STRIP
Weld back strip option
COUNTERSINK
value
0.000*
Countersink value for the Plug/Slot weld
DEFAULT_SCHEME
ANSI
D x D*, D1 x D2, Angle, None
ISO
A*, Z, Z1xZ2, Angle, None
Default dimensioning scheme for fillet welds. This parameter is not copied to the weld feature
DEFAULT_SPOT_DIA
value
0.50”/12.70 mm*
Default diameter for spot welds
FACE_OFFSET
value
0.000*
Face offset for weld
FEEDRATE
value
-1.000*
Feed rate of the welding machine’s head across the part (unit = assembly unit/hour)
FIELD
NO*
YES
Field weld, the physical location where a weld is created
GROOVE_ANGLE
value
45 degrees*
Angle of a groove or butt weld between welded components
INTERMITTENT
NO*
YES
Whether weld is intermittent (contains spaces between weld segments)
INTER_NUM_N_PITCH
NO*
YES
Enables entering the number of intermittent weld segments for intermittent welds when the pitch is defined by value
INTER_STAGGERED
NO*
YES
Adds staggered intermittent weld
LENGTH
value
(Read-only) Computed length of trajectory of the welding material
MACH_TYPE
MANUAL*
ROBOTIC
Machining type of the weld
MAX_ALLOWED_LENGTH
value
1000*
Maximum allowed length of the weld
MAX_ROOT_OPENING
value
100*
Maximum root opening
MIN_ALLOWED_LENGTH
value
0*
Minimum allowed length of the weld
MIN_ROOT_OPENING
value
0*
Minimum root opening
NEXT_LEADER_OPT
ON ENTITY*, INTERSECT, MIDPOINT, ON SURFACE
Leader type for the next symbol leader
NUM_OF_WELDS
value
4.000*
Number of intermittent weld segments
OTHER_SIDE_SYMB
NO*
YES
Create symbol on the other side of the weld joint
PITCH_DIST
value
0.000*
Pitch distance between intermittent weld segments
Could exist in versions earlier than Creo 8. Not used in Creo 8 and later
PITCH_DIST_ANGULAR
value
90.000*
Pitch distance between intermittent weld segments for Angular type of intermittency
PITCH_DIST_LINEAR
value
1.000*
Pitch distance between intermittent weld segments for Linear type of intermittency
PLUG_SIZE
value
0.000*
Depth of the plug weld
PREP_DEPTH
value
0.25”/6.00 mm*
The preparation depth of a weld
ROOT_OPEN
value
0.25”/6.00 mm*
The size of the root opening between welded components
ROOT_PENETRATION
value
0.25”/6.00 mm*
Root penetration depth
SEG_LENGTH
value
0.000*
Length of each intermittent weld segment
Could exist in versions earlier than Creo 8. Not used in Creo 8 and later
SEG_LENGTH _ANGULAR
value
30.000*
Length of each intermittent weld segment for Angular type of intermittency
SEG_LENGTH_LINEAR
value
1.000*
Length of each intermittent weld segment for Linear type of intermittency
SPECIFICATION_NUMBER
string
1EXXXXX*
Specification number of the weld
SPOT_DIAMETER
value
0.50”/12.70 mm*
Spot weld diameter
SPOT_PITCH
value
0.000*
The pitch distance between spot welds
SPOT_STRENGTH
value
0.000*
Strength of spot weld
TREATMENT
NONE
LOW_HYDROGEN*
PRE_HEATING
POST_HEATING
Treatment of the weld
USER_DEFINED
string
A user-defined parameter can be added to the list of parameters
WELD_LENGTH
value
(Read-only) Computed length of the (physical) weld bead
WELD_LWW_THICKNESS
value
0.000*
Curve thickness for a light weld. This parameter is not copied to the weld feature
WELD_MATERIAL
string
The filler material used to create a weld. Access the parameter from the weld preferences tools. This parameter is not copied to the weld feature
WELD_PROCESS
string
A defined process used to create a weld. This parameter is not copied to the weld feature
WELD_SIZE
value
0.25”/6.00 mm*
Size of a weld
WELD_SPACING
AT_CENTER*
AT_END
Start point for intermittent weld segments
X_SECTION_AREA
value
-1.000*
Cross sectional area of the weld
Parameters Available—ANSI
Parameter Name
Value
Definition
BACK_WELD_FINISH
NONE*
CHIP
HAMMER
GRIND
MACHINE
ROLL
UNSPECIFIED
The weld back finish
BACK_WELD_SHAPE
NONE*
FLAT
CONVEX
CONCAVE
The weld back contour
FINISH
None*
CHIP
HAMMER
GRIND
MACHINE
ROLL
UNSPECIFIED
Finishing process of the weld
LEG1
value
0.25”/6.00 mm*
Value given to the first leg of a fillet weld
LEG2
value
0.25”/6.00 mm*
Value given to the second leg of a fillet weld
SHAPE
NONE*
FLAT
CONVEX
CONCAVE
The weld contour
Parameters Available—ISO
Parameter Name
Value
Definition
BACK_WELD_FINISH
NO*
YES
The weld back finish
FINISH
NO*
YES
Finishing process of the weld
IDENT_LINE
YES*
NO
Show the identification line in the symbol
IDENT_LINE_POSITION
BELOW*
ABOVE
Location of the identification line in relation to the reference line
LEG_LENGTH
value
0.25”/6.00 mm*
Value given to the first leg of a fillet weld
LEG_LENGTH_2
value
0.25”/6.00 mm*
Value given to the second leg of a fillet weld, the Z2 dimension in a Z1 x Z2 dimensioning scheme
SHAPE
NONE*
FLAT
CONVEX
CONCAVE
SMOOTH_BLEND
The weld contour
NUM_OF_WELDS_OS
value
(Read only) Computed number of welds on the other side of the joint for intermittent and staggered double-sided welds
Used when the Pitch is Automatic and the Weld spacing is End with weld
THROAT_THICKNESS
value
0.50*
Value given to the distance from the weld surface to the trajectory
Was this helpful?