Displaying Segment Violations
Segment violation types are displayed under Design Rules Tree in the Design Rules Check dialog box as follows:
• Min Segment Length—Displays violation results if you create a pipe segment with a length shorter than the minimum segment length.
• Max Segment Length—Displays violation results if you create a pipe segment with a length greater than the maximum segment length.
The violation results are displayed in the following columns under Violation Details when you click Min Segment Length or Max Segment Length:
◦ Stockno—The stock number of the pipe.
◦ Current—The current segment length.
◦ Required—The required minimum or maximum segment length.
• Total Segment Length—Displays violation results if you create pipe segments of a pipe in the active assembly where the pipe segments have length greater than the total pipe length. The violation results are displayed in the following columns under Violation Details:
◦ Stockno—The stock number of the pipe.
◦ Current—The total segment length.
◦ Required—The required total segment length.