Tutoriales de Creo > Tutoriales de Creo Flow Analysis > Tutoriales adicionales > Tutorial 4 - Cavitation over an Orifice > Cavitation over an Orifice: Exercise 3—Defining Physics Modules
Cavitation over an Orifice: Exercise 3—Defining Physics Modules
1. In the Flow Analysis Tree, right-click Physics and select Select Physical Models. or click Physics Module. The Physical Model Selection dialog box opens.
2. Under Available Modules, select Turbulence and click
3. Under Available Modules, select Cavitation and click
4. Click Close to close the Physical Model Selection dialog box.
Specifying Flow Module Conditions
1. In the Flow Analysis Tree, under Physics select Flow.
2. In the Model tab select the following values for the options listed:
Under Relaxation, for Velocity set 0.5
Under Numerics, for Numeric Scheme set the following values:
Velocity2nd Order Upwind
PressureUpwind
Under Use Gauge Pressure, select No.
¿Fue esto útil?