Creo Simulate > Reference Links > At Each Step—Time Evaluation (Thermal Analysis)
At Each Step—Time Evaluation (Thermal Analysis)
Creo Simulate calculates the value of the measure at each time step.
The time step may vary by many orders of magnitude during the course of an analysis, depending on the loads and constraints. At the beginning of an analysis, the time step can be especially small. As the energy norm in the model is zero at the start of an analysis, the errors in energy norm are normalized by a small value.
The software does not report the measure values in the summary file, but you can plot these measures as a function of time when you create your analysis results.