電力設計 > Using Notes in Diagram > Showing Diagram Parameters for Cables and Cable Conductors
Showing Diagram Parameters for Cables and Cable Conductors
To show diagram parameters, attach the following parametric note parameters to wires in a diagram cable:
&spool_name—Shows the name of the parent spool.
&spool_<parameter>—Shows the value of a top-level spool parameter, for example, Color.
&cbl_name—Shows the cable name to which the wire belongs.
&cbl_<parameter>—Shows a specific cable parameter, for example target length, maximum allowed length, user-defined, and so on.
&cond_name—Shows the name of the spool conductor that has been assigned to that wire.
&cond_<spool parameter>—Shows a specific spool conductor parameter for that wire’s assigned conductor, for example, wire construction, color, user-defined, and so on.
* 
You can set Diagram to show the cable name and conductor number for a wire assigned to a cable by default. If you set the drawing configuration option cond_name_from_cable to YES, the wire label shows the cable name and conductor name instead of the wire name for any wires added to a cable and assigned a conductor number.
For Cable Symbols
You can enter &cbl_name, &cbl_<parameter>, &spool_name, and &spool_<parameter name> for note to display the cable name, spool name, or any cable or spool parameter.
這是否有幫助?