Simulation > Creo Simulate > Reference Links > Measure Convergence
Measure Convergence
The Structure engine calculates and reports in the summary report the convergence percentage of each measure. The convergence index is the maximum percentage change of any measure. The percentage change is the difference between the current pass and the preceding pass divided by the value at the current pass. For multiple load sets, the value is the maximum over all load sets.