To Define a Phase Measure
This procedure assumes you selected the Phase quantity on the Measure Definition dialog box.
1. Select an item from the second option menu to complete the
phase type.
2. Select one of the following components: Magnitude, X, Y, Z.
3. For the components X, Y, and Z, select a coordinate system.
5. With the arrow button, select a point or appropriate reference entities as required by your selection for spatial evaluation.
7. If you want to know the time at which a minimum, maximum, or maximum absolute condition occurs, select the
Time Stamp checkbox.
8. Review the list box at the bottom of the dialog box to determine which types of analyses are valid for the measure.
9. Click OK. Each of the custom measures shows up on the Measures dialog box.