To Setup a DMIS Text Data
1. Do one of the following:
Click Inspect > Inspection Machine > DMIS Text.
In the CMM Work Center dialog box, click the Probes tab and click DMIS.
The DMIS Text menu appears.
2. Click Create on the DMIS Text menu. The Activate DMIS Text dialog box opens.
3. Select the DMIS text for which you want to specify the output option and do one of the following:
Click Oper to display the selected DMIS text to the CMM screen.
Click Outfil to output the selected DMIS test to the CMM output file.
Click Man to display the selected DMIS text to the CMM operator.
Click No if you do not want the selected DMIS text as output.
* 
To select all the DMIS text data, click . To clear the selection, click .
4. To enter comments for a DMIS text, highlight the DMIS text and type the comment in the Comments box. When you highlight an item with an existing comment, CMM displays the existing comment in the Comments text box. While editing a comment, you can revert to the previous value by clicking the drop-down arrow next to the Comments text box.
5. Click OK to finish setting up the DMIS text data.
6. Click Done/Return to return to the CMM Work Center dialog box.