Warning Messages
You must resolve any warning messages that may appear while validating and checking the wireframe assembly. Explanations of these messages with their resolutions follow.
Warning
Description
Resolution
Cannot fit the flattened harness view into the selected drawing template.
The flattened harness part does not fit into the any of the drawing templates.
Do one of the following:
Click Bend to Fit to bend the longer branches.
Adjust the scaling factor.
Click Variable sheet size to use a drawing sheet size that expands in the horizontal direction to fit the branches.
Select a larger drawing template.
Define a custom drawing template.
* 
The 2D representation must fit in a single drawing sheet. You cannot split a 2D representation across multiple sheets.
Cannot prevent branch overlap.
The manufacturing drawing contains overlapping branches.
You must re-orient the branches on the manufacturing drawing to remove overlaps.
Cannot automatically dimension segments. Check message log for details.
The specified branch segment cannot be automatically dimensioned.
The IDs of the segment that were not dimensioned are written to the error log file. Manually add dimension to the segment.
Cannot find terminator information. Check cavity tables.
The terminators for the connector model could not be extracted.
The ID of the connector for which terminators were not extracted is written to the error log file. Ensure the terminators are added to the connector model either as an electrical or mechanical parameter.
Cannot generate component view. Check cavity tables.
The connector rear view could not be generated for the connector. The model name could not be extracted from the part.
The IDs of the connectors for which the rear views were not drawn are written to the error log file. Ensure the part is in session and is valid for the assembly. Re-flatten the harness. If the problem persists, contact PTC technical support.
Cannot process the sub-harness.
HMX was unable to process the sub-harness assembly due to an error.
Close and re-open the assembly. Open the HMX dialog box and flatten the sub-harness. If the problem persists, contact PTC technical support.
The Wire List table is incomplete
Not all extracted wires were added to the Wire List table.
The IDs of the missing wires are written to the error log file. re-flatten the harness. If the problem persists, contact PTC technical support.
The drawing template units differ from the user configuration file.
The drawing template units and the value specified for the configuration option pro_length_unit do not match. The generated drawing will be displayed incorrectly.
Use a different drawing template, or change the value of the configuration option pro_length_unit for the harness assembly in session.
Overlapping locations found.
Overlapping location points are found in the generated harness. The overlapping location points have the same X, Y, and Z coordinates.
To avoid overlapping locations do not insert locations close to each other.
Selected drawing template contains predefined drawing views.
No suitable drawing border format has been found.
Select a suitable drawing sheet template.
Only bundles are completely routed. Check if the HMX drawing is as expected.
Only bundles are routed. There are no wires in the harness. Bundles can be terminated on entry ports or location points. If the bundles are terminated on entry ports, the associated connectors and visible terminals appear in the manufacturing drawing. If the bundles are terminated on location points, the associated connectors and visible terminals do not appear in the manufacturing drawing.
Terminate bundles on entry ports or locations points to obtain the desired result.
Model "Description" parameter is not specified. Using default value.
You have not specified a value for the BOM reporting parameter, Model "Description". The default value DESCRIPTION will be used.
Map the BOM parameters to the appropriate property of the 3D assembly using the Model "Description" option.
Connector "Seal" parameter not specified. Using default value.
You have not specified a value for the BOM Reporting Parameter, Connector "Seal". The default value SEAL_NAME will be used.
Map the BOM parameters to the appropriate property of the 3D assembly using the Connector "Seal" option.
Spool "Part Number" parameter not specified. Using default value.
You have not specified a value for the BOM Reporting Parameter Spool "Part Number". The default value MANUFACTURER_PART_NO will be used.
Map the BOM parameters to the appropriate property of the 3D assembly using the Spool "Part Number" option.
Detected conductors within a bundle; wire lengths may be inaccurate.
Presence of conductors in a bundle may cause inaccurate calculation of the wire lengths.
The IDs of the bundles that contain conductors are written to the error log file. Route conductors outside the bundle.
* 
This error does not apply to wires or cables within bundles.
Custom Symbol Library Missing Symbol Directory.
No symbol directory has been found.
Make sure the directory is accessible to the current machine and that it has not been moved.
Connector <Component name> symbol missing from symbol directory.
No symbol has been found in the symbol directory with the model name.
Add the symbol to the currently used symbol directory.
One or more errors have been detected in retrieving custom symbols. Reverting to generated cavity views.
An attempt to retrieve a symbol has failed.
The symbols used were unable to be retrieved, either by inability to access the directory or the symbols not present for the currently processed model. Rerun HMX after resolving the issues.