Electrical Design > Harness > Using Components in MFG Mode > To Attach Wires to Their Entry Ports
To Attach Wires to Their Entry Ports
1. Click CABLE MFG > Flatten > Components. The FLAT CONN menu appears.
2. Select either Fan Out or Fan Out All.
If you select Fan Out, you are prompted to select an assembled connector whose unattached wires you want to fan out.
If you select Fan Out All, all wires are attached to their respective entry ports if their lengths permit it.
All the wires attached to this connector in the reference harness are laid out in the flat harness and are automatically routed to their corresponding entry ports.