Use msengine
You can specify one or more of the following options after the input directory name:
• –i input_dir—Specifies the location of the directory containing the engine input files.
• –solram ram_size—Specifies the amount, in megabytes, of memory to be allocated for direct solver memory and for element data for the iterative solver.
• –iter n—Specifies that the engine uses the iterative solver after polynomial pass n, a number from 1 to 8.
• –sturm option—Specifies whether or not the Structure engine performs a Sturm sequence test for a modal analysis.
• –extopt—Specifies that
Creo Simulate uses an external optimizer to run either a function evaluation (using a standard study) or a gradient evaluation (using a local sensitivity study).
• –ascii—Specifies that the engine writes the engine output files in ASCII format.
• –bsram ram_size—Specifies the amount, in megabytes, of block solver RAM the engine uses for equation solving.
• –elram ram_size—Specifies the amount, in megabytes, of RAM available to store element matrices created by the iterative solver.
• –massnorm—Specifies that the Structure engine mass-normalizes mode shape vectors instead of unit-normalizing them in modal analysis.
• –pmax n—Specifies the maximum p-order in a transient thermal analysis.
• –no_pert—Suppresses perturbation solvers.